100-390/185 – Circulation pump

100-390/185 – Circulation pump

18.5 kW (25 HP) · Hmax 39 m · Qmax 210 t/h (3500 l/min) · DN 100 · 2900 rpm

Technical specifications

Select a value to find pumps with the same specification

Pump typeCirculation
Maximum flow (Qmax)210 t/h · 3500 l/min
Maximum head (Hmax)39 m
Power18.5 kW · 24.8 HP
Speed2900 rpm
Protection classIP55
Inlet (suction)4" (100 mm)
Outlet (discharge)4" (100 mm)
Maximum fluid temperature120 °C
Impeller materialCast iron
Insulation classF
Frequency50 Hz
SKU CIRC-100-390/185

Price

on request

Send an inquiry to receive prices and delivery terms within 1–2 days.

Send an inquiryContact us
  • Official dealer for 20+ brands
  • Delivery in Georgia
  • 20+ years of experience

Series comparison

The entire series in one table

5 Model in one family, with head at each flow. The model you are viewing is highlighted in dark blue.

ახალი სერია DN100 · 2900

This family
ახალი სერია DN100 · 2900 Family performance comparison
Modelt/h →l/min →Curve0090150010818001202000138230018030002103500
100-270/11011 kWVoltage not confirmed2727.32624.522.516-
100-320/15015 kWVoltage not confirmed32.832.531.330.228.522.116.7
100-390/185Current18.5 kWVoltage not confirmed393836.83633.828.823.5
100-480/22022 kWVoltage not confirmed4847.545.543.54132.524.5
100-600/30030 kWVoltage not confirmed6059.5585754.54740.5
Table 1. ახალი სერია DN100 · 2900 – columns show flow in t/h, with l/min below; cells show head in metres.

Source: manufacturer's technical sheet.Values are for reference. In a real system, pipe diameter, length and bends reduce the available head.

Technical sheet

Model 100-390/185

Performance curve

A pump has a performance curve rather than a single flow and head. Qmax and Hmax are at opposite ends and never occur together: at maximum head, flow is zero; at maximum flow, head is zero. Actual operation lies between these extremes.

Hmax 39 mQmax210 t/h3500 l/min010203040t/h050100150200250l/min01000200030004000Head, mFlow
Maximum head
39m

At zero flow

Maximum flow
210t/h

3500 l/min· at 23.5 m

Midpoint
36m

120 t/h
2000 l/minat

Chart 1. Head (m) against flow (t/h, l/min), 100-390/185. Blue points show the manufacturer's measured values. Move the pointer near the curve, or touch it on a phone, to read the head and flow at any point.

Measured values

Performance table
t/h
l/min
Head, m

Select a number in the table to see the corresponding point.

100-390/185 – Circulation pump · PN.GE