25-4-N180 – Circulation pump

25-4-N180 – Circulation pump

P1 180 W

Nameplate data

Maximum pressure10 bar
Maximum water temperature110 °C
Motor220 V · 50 Hz
Rated current0.8 A
Maximum consumption180 W
Insulation classF
Protection classIP44

Technical specifications

Select a value to find pumps with the same specification

Pump typeCirculation
Power0.18 kW · 0.2 HP
Protection classIP44
Maximum fluid temperature110 °C
Insulation classF
Frequency50 Hz
SKU CIRC25-25-4-N180

Price

on request

Send an inquiry to receive prices and delivery terms within 1–2 days.

Send an inquiryContact us
  • Official dealer for 20+ brands
  • Delivery in Georgia
  • 20+ years of experience

Manufacturer's tables

Technical data

Speed stages – nameplate data

StageP1 (W)Current (A)Head (m)Flow (l/min)
11000.45——
21300.6——
31800.8——

Series comparison

The entire series in one table

18 Model in one family, with head at each flow. The model you are viewing is highlighted in dark blue.

PBG

This family
PBG Family performance comparison
Modelt/h →l/min →Curve000.350.6100.9151.2201.5251.830233.332.1352.4402.7453503.3553.6603.9654.2704.5754.8805.1855.4905.79561006.31056.61106.91157.21207.51257.81308.11358.41408.714591509.31559.61609.916510.51751220013.52251525016.52751830018.9315
25-4-N1300.072 kW220 VApproximate43.943.753.4432.441.75-0.940--------------------------------
15-4-N1800.1 kW220 VApproximate43.893.5632.221.220-----------------------------------
32-4-N1800.072 kW220 VApproximate43.973.893.753.563.313-2.642.221.751.220.640----------------------------
20-4-N1800.072 kW230 VApproximate4.54.44.13.592.881.970.860----------------------------------
15-6-N1300.1 kW220 VApproximate65.915.635.164.53.662.63-1.410--------------------------------
20-6-1800.09 kW220 VApproximate65.945.765.465.044.53.84-3.062.161.140------------------------------
25-6-N1800.22 kW220 VApproximate65.985.935.835.75.545.33-5.094.814.54.153.763.332.872.371.831.260.650----------------------
20-8-N1800.22 kW220 VApproximate87.987.917.87.657.457.2-6.916.586.25.785.324.814.253.663.012.331.60.820---------------------
25-8-N1800.22 kW220 VApproximate87.987.917.87.657.457.2-6.916.586.25.785.324.814.253.663.012.331.60.820---------------------
32-8-N1800.235 kW220 VApproximate87.997.947.887.787.657.5-7.327.116.886.616.3265.655.284.884.443.993.52.992.441.881.280.650----------------
15PBG-9-N1600.12 kW220 VApproximate98.868.447.736.755.483.94-2.110--------------------------------
20-10-N1800.32 kW220 VApproximate109.999.959.899.819.79.57-9.429.249.048.818.568.297.997.677.326.966.566.155.715.244.764.243.713.152.571.961.330.680-----------
25-10N1800.32 kW220 VApproximate109.999.969.919.839.749.63-9.499.339.168.968.748.58.247.967.667.346.996.636.245.845.414.964.54.013.52.972.411.841.250.630---------
32-10N1800.32 kW220 VApproximate109.999.969.929.859.779.67-9.559.419.269.088.898.688.458.27.937.657.357.026.696.335.955.565.144.714.263.793.312.82.281.741.180.60-------
50PBG-160.55 kW220 VApproximate16----15.84-----15.36----14.56----13.44----12----10.24---8.165.763.040---
50PBG-211.1 kW220 VApproximate21----20.87-----20.47----19.81----18.88----17.69----16.24---14.5212.5310.297.774.991.950
25-4-N180Current0.18 kW220 VCurve not entered yet
32-6-N1800.084 kW220 VCurve not entered yet
Table 1. PBG – columns show flow in t/h, with l/min below; cells show head in metres.

Curves marked “approximate” are calculated from nameplate data and are not factory test results.Values are for reference. In a real system, pipe diameter, length and bends reduce the available head.

25-4-N180 – Circulation pump · PN.GE