65-400/75 – Circulation pump

65-400/75 – Circulation pump

7.5 kW (10 HP) · Hmax 40 m · Qmax 90 t/h (1500 l/min) · DN 65 · 2900 rpm

Technical specifications

Select a value to find pumps with the same specification

Pump typeCirculation
Maximum flow (Qmax)90 t/h · 1500 l/min
Maximum head (Hmax)40 m
Power7.5 kW · 10 HP
Speed2900 rpm
Protection classIP55
Inlet (suction)2½" (65 mm)
Outlet (discharge)2½" (65 mm)
Maximum fluid temperature120 °C
Impeller materialCast iron
Insulation classF
Frequency50 Hz
SKU CIRC-65-400/75

Price

on request

Send an inquiry to receive prices and delivery terms within 1–2 days.

Send an inquiryContact us
  • Official dealer for 20+ brands
  • Delivery in Georgia
  • 20+ years of experience

Series comparison

The entire series in one table

7 Model in one family, with head at each flow. The model you are viewing is highlighted in dark blue.

ახალი სერია DN65 · 2900

This family
ახალი სერია DN65 · 2900 Family performance comparison
Modelt/h →l/min →Curve0018300244002745036600427004880054900721200841400901500
65-140/111.1 kWVoltage not confirmed14.713.511.510.15.8------
65-180/151.5 kWVoltage not confirmed18.1171513.99.66-----
65-240/222.2 kWVoltage not confirmed24.523.221.520.216138.3----
65-310/303 kWVoltage not confirmed31.829.527.526.321.517.5-----
65-320/555.5 kWVoltage not confirmed32---30.6302826.620.514.8-
65-380/404 kWVoltage not confirmed3836343328.52520.1----
65-400/75Current7.5 kWVoltage not confirmed40---38373634.4292421
Table 1. ახალი სერია DN65 · 2900 – columns show flow in t/h, with l/min below; cells show head in metres.

Source: manufacturer's technical sheet.Values are for reference. In a real system, pipe diameter, length and bends reduce the available head.

Technical sheet

Model 65-400/75

Performance curve

A pump has a performance curve rather than a single flow and head. Qmax and Hmax are at opposite ends and never occur together: at maximum head, flow is zero; at maximum flow, head is zero. Actual operation lies between these extremes.

Hmax 40 mQmax90 t/h1500 l/min010203040t/h020406080100l/min050010001500Head, mFlow
Maximum head
40m

At zero flow

Maximum flow
90t/h

1500 l/min· at 21 m

Midpoint
34.4m

54 t/h
900 l/minat

Chart 1. Head (m) against flow (t/h, l/min), 65-400/75. Blue points show the manufacturer's measured values. Move the pointer near the curve, or touch it on a phone, to read the head and flow at any point.

Measured values

Performance table
t/h
l/min
Head, m

Select a number in the table to see the corresponding point.

65-400/75 – Circulation pump · PN.GE