80-330/92 – Circulation pump

80-330/92 – Circulation pump

9.2 kW (12.5 HP) · Hmax 33 m · Qmax 120 t/h (2000 l/min) · DN 80 · 2900 rpm

Technical specifications

Select a value to find pumps with the same specification

Pump typeCirculation
Maximum flow (Qmax)120 t/h · 2000 l/min
Maximum head (Hmax)33 m
Power9.2 kW · 12.3 HP
Speed2900 rpm
Protection classIP55
Inlet (suction)3" (80 mm)
Outlet (discharge)3" (80 mm)
Maximum fluid temperature120 °C
Impeller materialCast iron
Insulation classF
Frequency50 Hz
SKU CIRC-80-330/92

Price

on request

Send an inquiry to receive prices and delivery terms within 1–2 days.

Send an inquiryContact us
  • Official dealer for 20+ brands
  • Delivery in Georgia
  • 20+ years of experience

Series comparison

The entire series in one table

6 Model in one family, with head at each flow. The model you are viewing is highlighted in dark blue.

ახალი სერია DN80 · 2900

This family
ახალი სერია DN80 · 2900 Family performance comparison
Modelt/h →l/min →Curve004880054900721200841400901500108180012020001382300
80-190/404 kWVoltage not confirmed1917.316.814.51311.8---
80-230/555.5 kWVoltage not confirmed2321.320.91917.516.713.7--
80-270/757.5 kWVoltage not confirmed272625.624.52322.52018-
80-330/92Current9.2 kWVoltage not confirmed33-31.5302827.12421.5-
80-360/11011 kWVoltage not confirmed36-34.53331.530.82825.5-
80-420/15015 kWVoltage not confirmed42-414038.537.8353329.5
Table 1. ახალი სერია DN80 · 2900 – columns show flow in t/h, with l/min below; cells show head in metres.

Source: manufacturer's technical sheet.Values are for reference. In a real system, pipe diameter, length and bends reduce the available head.

Technical sheet

Model 80-330/92

Performance curve

A pump has a performance curve rather than a single flow and head. Qmax and Hmax are at opposite ends and never occur together: at maximum head, flow is zero; at maximum flow, head is zero. Actual operation lies between these extremes.

Hmax 33 mQmax120 t/h2000 l/min010203040t/h020406080100120l/min0500100015002000Head, mFlow
Maximum head
33m

At zero flow

Maximum flow
120t/h

2000 l/min· at 21.5 m

Midpoint
28m

84 t/h
1400 l/minat

Chart 1. Head (m) against flow (t/h, l/min), 80-330/92. Blue points show the manufacturer's measured values. Move the pointer near the curve, or touch it on a phone, to read the head and flow at any point.

Measured values

Performance table
t/h
l/min
Head, m

Select a number in the table to see the corresponding point.

80-330/92 – Circulation pump · PN.GE