WRS65-2200F – Circulation pump

WRS65-2200F – Circulation pump

P1 2200 W · Hmax 20 m · Qmax 28.8 t/h (480 l/min)

Nameplate data

Maximum flow28.8 t/h · 480 l/min
Maximum head20 m
Maximum pressure10 bar
Maximum water temperature110 °C
Motor220 V · 50 Hz
Rated current10 A
Maximum consumption2200 W
Insulation classF
Protection classIP44

Technical specifications

Select a value to find pumps with the same specification

Pump typeCirculation
Maximum flow (Qmax)28.8 t/h · 480 l/min
Maximum head (Hmax)20 m
Power2.2 kW · 2.9 HP
Protection classIP44
Maximum fluid temperature110 °C
Insulation classF
Frequency50 Hz
SKU CIRC25-WRS65-2200F

Price

on request

Send an inquiry to receive prices and delivery terms within 1–2 days.

Send an inquiryContact us
  • Official dealer for 20+ brands
  • Delivery in Georgia
  • 20+ years of experience

Series comparison

The entire series in one table

2 Model in one family, with head at each flow. The model you are viewing is highlighted in dark blue.

WRS

This family
WRS Family performance comparison
Modelt/h →l/min →Curve001.5253504.57561007.5125915010.51751220013.52251525016.52751830019.232019.53252135022.53752440025.54252745028.547528.8480
WRS65-2200FCurrent2.2 kW220 VApproximate2019.9519.7819.5119.1318.6418.0517.3416.5315.6114.5713.4412.19-10.839.377.796.114.322.420.410
WRS40-1500F1.5 kW220 VApproximate2322.8622.4421.7420.7519.4917.9516.1214.0211.638.966.012.790--------
Table 1. WRS – columns show flow in t/h, with l/min below; cells show head in metres.

Curves marked “approximate” are calculated from nameplate data and are not factory test results.Values are for reference. In a real system, pipe diameter, length and bends reduce the available head.

Technical sheet

Model WRS65-2200F

Performance curve

A pump has a performance curve rather than a single flow and head. Qmax and Hmax are at opposite ends and never occur together: at maximum head, flow is zero; at maximum flow, head is zero. Actual operation lies between these extremes.

Hmax 20 mQmax28.8 t/h480 l/min05101520t/h051015202530l/min0100200300400500Head, mFlow
Maximum head
20m

At zero flow

Maximum flow
28.8t/h

480 l/min · at zero head

Midpoint
14.57m

15 t/h
250 l/minat

Chart 1. Head (m) against flow (t/h, l/min), WRS65-2200F. No manufacturer's table is available for this model. The approximate curve is calculated from nameplate maximum head and flow. Move the pointer near the curve, or touch it on a phone, to read the head and flow at any point.

Calculated values (from nameplate)

Performance table
t/h
l/min
Head, m

Select a number in the table to see the corresponding point.

WRS65-2200F – Circulation pump · PN.GE