FE PETRO MLD — leak detector service parts – series illustration

Series illustration

FE PETRO MLD — leak detector service parts

Service parts for MLD+ and high-capacity MLD-HC detectors. Match the factory code and detector model when choosing kits, covers, tubes and adapters.

Model code (SKU)PN-FF-400440101
Model
400440101
Factory order code
400440101
brands
FE PETRO / Franklin Electric
Product type
Pipe

Price

on request

Send an inquiry to receive prices and delivery terms within 1–2 days.

Send an inquiryContact us
  • Official dealer for 20+ brands
  • Delivery in Georgia
  • 20+ years of experience

Select a model by clicking its data in the table.

Compare models

ModelProduct type
Pipe
—
—
Adapter
Pipe
Cover
Cover
—

Construction, operation and model selection

Detailed description and use

System application and installation

Installed, grouped and component views

Vent connection to the tank
MLD-HC adapter and tank return

Replacement part within the assembly

Use the exploded-view position to identify the exact part code; the context image shows where it works in the pump or control enclosure. Replacement checks code, sealing, dimensions and electrical rating. Avoid damaging new seals, wires or cables during assembly, then verify the relevant pressure or electrical function.

Vent connection to the tank

The vent tube above the MLD+ installed in its 2″ NPT socket connects to the manifold’s TANK port. It returns air displaced by the piston and any drained liquid to the tank. The tube must remain unkinked and drain freely. The manual distinguishes TANK from SYPHON: the detector vent must not connect to the syphon port.

Air removal and leak testing

Trapped air or vapour can delay MLD+ opening and cause slow delivery. The guide calls for an initial line-integrity check, air removal and a functional test using a simulated 3 gph leak at 10 psi. Testing is required at startup and periodically thereafter; the factory guide specifies at least annually. The PDF shows the test apparatus and sequence.

Full installation manuals and drawings

Consult the specific model’s factory manual for the complete installation/service sequence, connections and safety requirements.

Factory video guides

Syphon jet cleaning and replacement

Syphon jet cleaning and replacement

Watch video ↗
4″ pump check-valve replacement

4″ pump check-valve replacement

Watch video ↗
Controller fault codes

Controller fault codes

Watch video ↗
Submersible fuel-pump installation

Submersible fuel-pump installation

Watch video ↗
PMA pump-motor assembly replacement

PMA pump-motor assembly replacement

Watch video ↗
Pump lead assembly replacement

Pump lead assembly replacement

Watch video ↗
Electrical yoke replacement

Electrical yoke replacement

Watch video ↗

Detector tubes and installation kits

This group covers vent tubes, fitting packs and detector adapters for MLD+/MLD-HC systems. Copper tubes for MLD+G/D and stainless tubes for MLD+AG/BD correspond to their fuel executions. A spare part is not a complete detector and does not independently carry its detection rating. Confirm the compatible detector by factory code.

Select parts by factory code

Each table row represents a separate factory order code. Selection changes the part facts and original assembly entry. Visual similarity does not establish interchangeability: match the pump/controller family, voltage or dimensions and repair-kit contents. An assembly illustration does not mean every pictured component is included.

Factory photos and details

Select an image to enlarge

Purpose and operation
High-flow mechanical detection
Vent connection to the tank
MLD-HC adapter and tank return

Descriptions include series-wide and optional features. Check the selected model’s table and documents for its actual configuration.

Original description and contents — 400440101

Manufacturer data (English)

MLD+ Mechanical Leak Detector Repair Parts & Accessories

Model Number400440101
DescriptionVent tube (for use with MLD+G and MLD+D)
Series data and documents — Manufacturer data (English)

All models are capable of detecting line leaks equivalent to 3 gph at 10 psi (11.4 lph @ 0.70 bar) when installed properly with the appropriate fuels - all models will signal detection of leaks by restricting product delivery to less than 3 gpm (11.4 lpm) and taking more than 4 seconds to open

All models will remain in the open position during product delivery to manifold, with discharge pressures as low as 1 psi (0.07 bar) - all models will reset to "tripped" when line pressure delay is below 3 psi (0.21 bar) with pump off

Detects leaks up to 10 feet (3 meters) above the point of installation

Max. liquid viscosity of 70 SSU at 60 °F (15 °C)

Gasoline models (blue cover, MLD+G and MLD+AG) are also listed for fuel mixtures containing 20% MTBE, 20% ETBE or 17% TAME with gasoline as well as diesel fuels, fuel oils, kerosene, Avgas and jet fuels.

Diesel models (gold cover, MLD+D and MLD+BD) are also listed for kerosene applications

cULus listed.

Third party certified to comply with US EPA requirements 280.41 (B) and 280.44 (A) for continuous monitoring of pressurized piping.

Consult factory for other applicable approvals.

Standard Fuel MLD+ Mechanical Leak Detectors

Model NumberDescription
403168901STP-MLD+G for gas, single pack (blue cover, copper vent tube, brass fittings)
403168903STP-MLD+G for gas, three pack
403170901STP-MLD+D for diesel, single pack (gold cover, copper vent tube, brass fittings)
403170903STP-MLD+D for diesel, three pack
403172903STP-MLD+D combo, three pack (contains two STP-MLD+G and one STP-MLD+D

Biofuel MLD+ Mechanical Leak Detectors

Model NumberDescription
403169901STP-MLD+AG for alcohol-gas, single pack (blue cover, stainless steel tube and fittings)
403169903STP-MLD+AG for alcohol-gas, three pack
403171901STP-MLD+BD for biodiesel, single pack (gold cover, stainless steel tube and fittings)
403171903STP-MLD+BD for biodiesel, three pack

MLD+ Mechanical Leak Detector Repair Parts & Accessories

Model NumberDescription
400440101Vent tube (for use with MLD+G and MLD+D)
400449903Hardware pack (fittings and documentation for MLD+G and MLD+D)
400449904Hardware pack (fittings and documentation for MLD+AG and MLD+BD)
400518001Leak detector Adapter tee
403123001Vent tube, stainless steel (for use with MLD+AG and MLD+BD)
Source page ↗ Franklin Electric Fueling Systems

About this product

Description

Service parts for MLD+ and high-capacity MLD-HC detectors. Match the factory code and detector model when choosing kits, covers, tubes and adapters.