HPC — Self-regulating heating cable – series illustration

Series illustration

Series illustration

HPC — Self-regulating heating cable

HPC — Self-regulating heating cable. Read more →

Shared series photographs · See the selected row for model electrical ratings.

Select Model:15HPC2-SF
Model code (SKU)PN-HT-HPC-9243FF0A
Model
15HPC2-SF
Power per unit length (W/m)
15
Maximum maintenance temperature (°C)
210
Maximum length at +10°C (m) · 16/32/50 A
120/169/169
Maximum length at 0°C (m) · 16/32/50 A
118/169/169
Maximum length at −20°C (m) · 16/32/50 A
98/169/169
Overall dimensions (mm)
10.8×5.0
Weight (kg/100 m)
12.5
Maximum exposure temperature (°C)
260

Price

on request

Send an inquiry to receive prices and delivery terms within 1–2 days.

Send an inquiryContact us
  • Official dealer for 20+ brands
  • Delivery in Georgia
  • 20+ years of experience

Select a model by clicking its data in the table.

Dimensions and specifications

ModelPower per unit length (W/m)Maximum maintenance temperature (°C)Maximum length at +10°C (m) · 16/32/50 AMaximum length at 0°C (m) · 16/32/50 AMaximum length at −20°C (m) · 16/32/50 AOverall dimensions (mm)
15HPC2-SF15210120/169/169118/169/16998/169/16910.8×5.0
30HPC2-SF3021081/118/18875/118/11865/118/11810.8×5.0
45HPC2-SF4521061/100/10057/100/10048/98/10010.8×5.0
60HPC2-SF6021048/87/8743/87/8730/82/8710.8×5.0
75HPC2-SF7521032/71/7524/54/7517/39/6010.8×5.0
90HPC2-SF9021020/40/6216/30/4810/22/3410.8×5.0

About this product

Description

HPC — Self-regulating heating cable. Operation and application A self-regulating matrix between parallel bus wires changes heat output with the local temperature. Colder sections produce more heat; output falls as they warm. Series variants differ in output per metre, jacket and temperature limits. Applications include pipework, vessels and process equipment heat tracing. Selecting a model The series includes 6 model configurations. Compare the selected configuration’s electrical ratings, dimensions and operating environment. Each value in the model table belongs to that particular row. Heating-system components are selected together for compatibility within the complete circuit. Installation planning Installation planning considers the power supply, controls, protective devices and the conditions where the product is fitted. The technical table supports comparison of the available configuration; the final circuit layout is matched to the specific installation. Shared series data Maximum maintenance temperature (°C): 210; Overall dimensions (mm): 10.8×5.0; Weight (kg/100 m): 12.5; Maximum exposure temperature (°C): 260.