55 kW (75 HP) · Hmax 70 m · Qmax 360 t/h (6000 l/min) · DN 150x125 · 2900 rpm

Technical specifications

Select a value to find pumps with the same specification

Pump typeIndustrial
Maximum flow (Qmax)360 t/h · 6000 l/min
Maximum head (Hmax)70 m
Power55 kW · 73.7 HP
Speed2900 rpm
Protection classIP55
Inlet (suction)6" (150 mm)
Outlet (discharge)5" (125 mm)
Maximum fluid temperature120 °C
Casing materialCast iron
Impeller materialCast iron
Insulation classF
Frequency50 Hz
SKU PST-125-250/550

Price

on request

Send an inquiry to receive prices and delivery terms within 1–2 days.

Send an inquiryContact us
  • Official dealer for 20+ brands
  • Delivery in Georgia
  • 20+ years of experience

Series comparison

The entire series in one table

11 Model in one family, with head at each flow. The model you are viewing is highlighted in dark blue.

PST 125 · 2900

This family
PST 125 · 2900 Family performance comparison
Modelt/h →l/min →Curve00120200014424001803000200333321035002203666240400028046663005000360600040066665008333
125-200/45045 kWVoltage not confirmed39.839.339.23938.938.938.837.5353428.625-
125-200/55055 kWVoltage not confirmed49.849.349.24948.948.948.847.5454438.635-
125-200/75075 kWVoltage not confirmed60.860.360.26059.959.959.858.5565549.646-
125-250/550Current55 kWVoltage not confirmed7067656463626159.5575653--
125-250/75075 kWVoltage not confirmed8077757473727169.867.166.26358.5-
125-250/90090 kWVoltage not confirmed878482818079787774.573.570.265.7-
125-315/90090 kWVoltage not confirmed89---87868583.781.581777461
125-250/1100110 kWVoltage not confirmed979492919089888784.683.980.476-
125-315/1100110 kWVoltage not confirmed103---1011009997.895.59591.588.275.6
125-315/1320132 kWVoltage not confirmed118---116115114112.5110.5110.3106.5103.291
125-315/1600160 kWVoltage not confirmed138---136.8135.9135133.7131.5131127.5124.2112
Table 1. PST 125 · 2900 – columns show flow in t/h, with l/min below; cells show head in metres.

Source: manufacturer's technical sheet.Values are for reference. In a real system, pipe diameter, length and bends reduce the available head.

Technical sheet

Model 125-250/550

Performance curve

A pump has a performance curve rather than a single flow and head. Qmax and Hmax are at opposite ends and never occur together: at maximum head, flow is zero; at maximum flow, head is zero. Actual operation lies between these extremes.

Hmax 70 mQmax360 t/h6000 l/min02550t/h0100200300400l/min0200040006000Head, mFlow
Maximum head
70m

At zero flow

Maximum flow
360t/h

6000 l/min· at 53 m

Midpoint
62m

210 t/h
3500 l/minat

Chart 1. Head (m) against flow (t/h, l/min), 125-250/550. Blue points show the manufacturer's measured values. Move the pointer near the curve, or touch it on a phone, to read the head and flow at any point.

Measured values

Performance table
t/h
l/min
Head, m

Select a number in the table to see the corresponding point.