PST 150-250/1100 - ინდუსტრიული ტუმბო

PST 150-250/1100 - ინდუსტრიული ტუმბო

110 kW (150 HP) · Hmax 67 m · Qmax 800 t/h (13333 l/min) · DN 200x150 · 2900 rpm

Technical specifications

Select a value to find pumps with the same specification

Pump typeIndustrial
Maximum flow (Qmax)800 t/h · 13333 l/min
Maximum head (Hmax)67 m
Power110 kW · 147.5 HP
Speed2900 rpm
Protection classIP55
Inlet (suction)8" (200 mm)
Outlet (discharge)6" (150 mm)
Maximum fluid temperature120 °C
Casing materialCast iron
Impeller materialCast iron
Insulation classF
Frequency50 Hz
SKU PST-150-250/1100

Price

on request

Send an inquiry to receive prices and delivery terms within 1–2 days.

Send an inquiryContact us
  • Official dealer for 20+ brands
  • Delivery in Georgia
  • 20+ years of experience

Series comparison

The entire series in one table

9 Model in one family, with head at each flow. The model you are viewing is highlighted in dark blue.

PST 150 · 2900

This family
PST 150 · 2900 Family performance comparison
Modelt/h →l/min →Curve0022036662404000280466630050003606000400666650083336001000080013333100016666
150-200/75075 kWVoltage not confirmed504847.947.647.246.746.440.636.825.2-
150-200/90090 kWVoltage not confirmed565453.953.653.252.752.44842.831.2-
150-200/1100110 kWVoltage not confirmed65.26261.761.260.859.859.257.25446-
150-250/1100Current110 kWVoltage not confirmed67---64.26260.655.849.833.8-
150-250/1320132 kWVoltage not confirmed80.2---78.276.37570.66550.229.8
150-250/1600160 kWVoltage not confirmed90---88.487868277.262.442
150-315/1600160 kWVoltage not confirmed92---9088.387.282.876.860.4-
150-315/2000200 kWVoltage not confirmed111---110.6108.7107.4103.498.283.462.2
150-315/2500250 kWVoltage not confirmed135---135.4133.7132.6128.6123.8110.291
Table 1. PST 150 · 2900 – columns show flow in t/h, with l/min below; cells show head in metres.

Source: manufacturer's technical sheet.Values are for reference. In a real system, pipe diameter, length and bends reduce the available head.

Technical sheet

Model 150-250/1100

Performance curve

A pump has a performance curve rather than a single flow and head. Qmax and Hmax are at opposite ends and never occur together: at maximum head, flow is zero; at maximum flow, head is zero. Actual operation lies between these extremes.

Hmax 67 mQmax800 t/h13333 l/min02550t/h0200400600800l/min0500010000Head, mFlow
Maximum head
67m

At zero flow

Maximum flow
800t/h

13333 l/min· at 33.8 m

Midpoint
60.6m

400 t/h
6666 l/minat

Chart 1. Head (m) against flow (t/h, l/min), 150-250/1100. Blue points show the manufacturer's measured values. Move the pointer near the curve, or touch it on a phone, to read the head and flow at any point.

Measured values

Performance table
t/h
l/min
Head, m

Select a number in the table to see the corresponding point.

PST 150-250/1100 - ინდუსტრიული ტუმბო · PN.GE