55 kW (75 HP) · Hmax 31.1 m · Qmax 837 t/h (13950 l/min) · DN 250x200 · 1450 rpm

Technical specifications

Select a value to find pumps with the same specification

Pump typeIndustrial
Maximum flow (Qmax)837 t/h · 13950 l/min
Maximum head (Hmax)31 m
Power55 kW · 73.7 HP
Speed1450 rpm
Protection classIP55
Inlet (suction)250 mm
Outlet (discharge)8" (200 mm)
Maximum fluid temperature120 °C
Casing materialCast iron
Impeller materialCast iron
Insulation classF
Frequency50 Hz
SKU PST-200-315/550

Price

on request

Send an inquiry to receive prices and delivery terms within 1–2 days.

Send an inquiryContact us
  • Official dealer for 20+ brands
  • Delivery in Georgia
  • 20+ years of experience

Series comparison

The entire series in one table

10 Model in one family, with head at each flow. The model you are viewing is highlighted in dark blue.

PST 200 · 1450

This family
PST 200 · 1450 Family performance comparison
Modelt/h →l/min →Curve0013722832253750312520040066674878117575958366211033750125008371395092515417
200-250/18518.5 kWVoltage not confirmed15.715.314.813.712.210.68.96.8---
200-250/22022 kWVoltage not confirmed18.5-17.216.214.813.111.18.7---
200-250/30030 kWVoltage not confirmed23.1-21.520.519.417.91613.610.8--
200-315/550Current55 kWVoltage not confirmed31.1-30.229.829.127.925.82319.214.8-
200-315/75075 kWVoltage not confirmed35.1-34.33433.33229.927.123.419.1-
200-400/75075 kWVoltage not confirmed41-40.640.339.437.73531.326.5--
200-315/90090 kWVoltage not confirmed42.1-41.34140.33936.934.130.426.1-
200-400/90090 kWVoltage not confirmed46.5-4645.744.943.441.137.733.327.9-
200-400/1100110 kWVoltage not confirmed52.4-52.251.951.2504845.141.236.2-
200-400/1320132 kWVoltage not confirmed60.1-59.859.65957.956.153.55045.439.6
Table 1. PST 200 · 1450 – columns show flow in t/h, with l/min below; cells show head in metres.

Source: manufacturer's technical sheet.Values are for reference. In a real system, pipe diameter, length and bends reduce the available head.

Technical sheet

Model 200-315/550

Performance curve

A pump has a performance curve rather than a single flow and head. Qmax and Hmax are at opposite ends and never occur together: at maximum head, flow is zero; at maximum flow, head is zero. Actual operation lies between these extremes.

Hmax 31.1 mQmax837 t/h13950 l/min010203040t/h02004006008001000l/min050001000015000Head, mFlow
Maximum head
31.1m

At zero flow

Maximum flow
837t/h

13950 l/min· at 14.8 m

Midpoint
27.9m

487 t/h
8117 l/minat

Chart 1. Head (m) against flow (t/h, l/min), 200-315/550. Blue points show the manufacturer's measured values. Move the pointer near the curve, or touch it on a phone, to read the head and flow at any point.

Measured values

Performance table
t/h
l/min
Head, m

Select a number in the table to see the corresponding point.