PST 32-250/75D - ინდუსტრიული ტუმბო

PST 32-250/75D - ინდუსტრიული ტუმბო

7.5 kW (10 HP) · Hmax 95 m · Qmax 24 t/h (400 l/min) · DN 50x32 · 2900 rpm

Technical specifications

Select a value to find pumps with the same specification

Pump typeIndustrial
Maximum flow (Qmax)24 t/h · 400 l/min
Maximum head (Hmax)95 m
Power7.5 kW · 10 HP
Speed2900 rpm
Protection classIP55
Inlet (suction)2" (50 mm)
Outlet (discharge)1¼" (32 mm)
Maximum fluid temperature120 °C
Casing materialCast iron
Impeller materialStainless steel
Insulation classF
Frequency50 Hz
SKU PST-32-250/75D

Price

on request

Send an inquiry to receive prices and delivery terms within 1–2 days.

Send an inquiryContact us
  • Official dealer for 20+ brands
  • Delivery in Georgia
  • 20+ years of experience

Series comparison

The entire series in one table

12 Model in one family, with head at each flow. The model you are viewing is highlighted in dark blue.

PST 32 · 2900

This family
PST 32 · 2900 Family performance comparison
Modelt/h →l/min →Curve006100915015250183002440027450
32-125/070.75 kWVoltage not confirmed17.516.715129--
32-125/111.1 kWVoltage not confirmed222119.716.514.59-
32-160/151.5 kWVoltage not confirmed25.423.722.518.515.8--
32-160/222.2 kWVoltage not confirmed3129.628.524.52215-
32-160/303 kWVoltage not confirmed3534.3342825.51915
32-200/303 kWVoltage not confirmed44.24339.835.232.224.619.8
32-200/404 kWVoltage not confirmed54.5525045.541.93530.3
32-250/555.5 kWVoltage not confirmed6059.559555134.5-
32-250/757.5 kWVoltage not confirmed69.56968.5666353-
32-250/55D5.5 kWVoltage not confirmed79.574.771.8635637.5-
32-250/11011 kWVoltage not confirmed9089.589827966-
32-250/75DCurrent7.5 kWVoltage not confirmed959391837657.8-
Table 1. PST 32 · 2900 – columns show flow in t/h, with l/min below; cells show head in metres.

Source: manufacturer's technical sheet.Values are for reference. In a real system, pipe diameter, length and bends reduce the available head.

Technical sheet

Model 32-250/75D

Performance curve

A pump has a performance curve rather than a single flow and head. Qmax and Hmax are at opposite ends and never occur together: at maximum head, flow is zero; at maximum flow, head is zero. Actual operation lies between these extremes.

Hmax 95 mQmax24 t/h400 l/min0255075100t/h0510152025l/min0100200300400Head, mFlow
Maximum head
95m

At zero flow

Maximum flow
24t/h

400 l/min· at 57.8 m

Midpoint
83m

15 t/h
250 l/minat

Chart 1. Head (m) against flow (t/h, l/min), 32-250/75D. Blue points show the manufacturer's measured values. Move the pointer near the curve, or touch it on a phone, to read the head and flow at any point.

Measured values

Performance table
t/h
l/min
Head, m

Select a number in the table to see the corresponding point.

PST 32-250/75D - ინდუსტრიული ტუმბო · PN.GE