PST 80-125/40 - ინდუსტრიული ტუმბო

PST 80-125/40 - ინდუსტრიული ტუმბო

4 kW (5.5 HP) · Hmax 17 m · Qmax 120 t/h (2000 l/min) · DN 100x80 · 2900 rpm

Technical specifications

Select a value to find pumps with the same specification

Pump typeIndustrial
Maximum flow (Qmax)120 t/h · 2000 l/min
Maximum head (Hmax)17 m
Power4 kW · 5.4 HP
Speed2900 rpm
Protection classIP55
Inlet (suction)4" (100 mm)
Outlet (discharge)3" (80 mm)
Maximum fluid temperature120 °C
Casing materialCast iron
Impeller materialCast iron
Insulation classF
Frequency50 Hz
SKU PST-80-125/40

Price

on request

Send an inquiry to receive prices and delivery terms within 1–2 days.

Send an inquiryContact us
  • Official dealer for 20+ brands
  • Delivery in Georgia
  • 20+ years of experience

Series comparison

The entire series in one table

3 Model in one family, with head at each flow. The model you are viewing is highlighted in dark blue.

PST 80-125 · 2900

This family
PST 80-125 · 2900 Family performance comparison
Modelt/h →l/min →Curve004880054900721200841400901500108180012020001382300
80-125/40Current4 kWVoltage not confirmed1716.515.914.313.511.6107.5-
80-125/555.5 kWVoltage not confirmed2120.520191816.51512.59.5
80-125/757.5 kWVoltage not confirmed26252524.523.822.521.519.516.5
Table 1. PST 80-125 · 2900 – columns show flow in t/h, with l/min below; cells show head in metres.

Source: manufacturer's technical sheet.Values are for reference. In a real system, pipe diameter, length and bends reduce the available head.

Technical sheet

Model 80-125/40

Performance curve

A pump has a performance curve rather than a single flow and head. Qmax and Hmax are at opposite ends and never occur together: at maximum head, flow is zero; at maximum flow, head is zero. Actual operation lies between these extremes.

Hmax 17 mQmax120 t/h2000 l/min05101520t/h020406080100120l/min0500100015002000Head, mFlow
Maximum head
17m

At zero flow

Maximum flow
120t/h

2000 l/min· at 7.5 m

Midpoint
13.5m

84 t/h
1400 l/minat

Chart 1. Head (m) against flow (t/h, l/min), 80-125/40. Blue points show the manufacturer's measured values. Move the pointer near the curve, or touch it on a phone, to read the head and flow at any point.

Measured values

Performance table
t/h
l/min
Head, m

Select a number in the table to see the corresponding point.

PST 80-125/40 - ინდუსტრიული ტუმბო · PN.GE