PST 80-315/900 - ინდუსტრიული ტუმბო

PST 80-315/900 - ინდუსტრიული ტუმბო

90 kW (125 HP) · Hmax 144 m · Qmax 240 t/h (4000 l/min) · DN 100x80 · 2900 rpm

Technical specifications

Select a value to find pumps with the same specification

Pump typeIndustrial
Maximum flow (Qmax)240 t/h · 4000 l/min
Maximum head (Hmax)144 m
Power90 kW · 120.6 HP
Speed2900 rpm
Protection classIP55
Inlet (suction)4" (100 mm)
Outlet (discharge)3" (80 mm)
Maximum fluid temperature120 °C
Casing materialCast iron
Impeller materialCast iron
Insulation classF
Frequency50 Hz
SKU PST-80-315/900

Price

on request

Send an inquiry to receive prices and delivery terms within 1–2 days.

Send an inquiryContact us
  • Official dealer for 20+ brands
  • Delivery in Georgia
  • 20+ years of experience

Series comparison

The entire series in one table

13 Model in one family, with head at each flow. The model you are viewing is highlighted in dark blue.

PST 80 · 2900

This family
PST 80 · 2900 Family performance comparison
Modelt/h →l/min →Curve006010009015001202000144240018030002003333210350022036662404000
80-160/11011 kWVoltage not confirmed272727.324.521.116----
80-160/15015 kWVoltage not confirmed32.832.632.530.22722.118.516.7--
80-160/18518.5 kWVoltage not confirmed3938.53836.733.628.825.323.5--
80-160/22022 kWVoltage not confirmed4443.54341.738.633.830.328.5--
80-200/22022 kWVoltage not confirmed4847.747.543.539.232.527.224.5--
80-200/30030 kWVoltage not confirmed6059.759.55753.14742.740.5--
80-250/37037 kWVoltage not confirmed71.570.970.565.559.35143.238.5--
80-315/45045 kWVoltage not confirmed858482.6827868.36156--
80-250/45045 kWVoltage not confirmed8886.78683.678.570.56051--
80-250/55055 kWVoltage not confirmed94.594.594.591.88779.572.168.3--
80-315/55055 kWVoltage not confirmed989795.6959181.37469--
80-315/75075 kWVoltage not confirmed124123121.6121117107.3100959080.8
80-315/900Current90 kWVoltage not confirmed144143141.6141137127.3120115110100.8
Table 1. PST 80 · 2900 – columns show flow in t/h, with l/min below; cells show head in metres.

Source: manufacturer's technical sheet.Values are for reference. In a real system, pipe diameter, length and bends reduce the available head.

Technical sheet

Model 80-315/900

Performance curve

A pump has a performance curve rather than a single flow and head. Qmax and Hmax are at opposite ends and never occur together: at maximum head, flow is zero; at maximum flow, head is zero. Actual operation lies between these extremes.

Hmax 144 mQmax240 t/h4000 l/min050100150t/h050100150200250l/min01000200030004000Head, mFlow
Maximum head
144m

At zero flow

Maximum flow
240t/h

4000 l/min· at 100.8 m

Midpoint
127.3m

180 t/h
3000 l/minat

Chart 1. Head (m) against flow (t/h, l/min), 80-315/900. Blue points show the manufacturer's measured values. Move the pointer near the curve, or touch it on a phone, to read the head and flow at any point.

Measured values

Performance table
t/h
l/min
Head, m

Select a number in the table to see the corresponding point.

PST 80-315/900 - ინდუსტრიული ტუმბო · PN.GE