Technical tables and curves
PENTAX · 12LM · 50 Hz
Select a model (36)
Select a model in the table to display its curve and data below.
| Model | Q range (m³/h) | H range (m) |
|---|---|---|
| 0–360 | 29–41 | |
| 0–420 | 34–49 | |
| 0–420 | 42–62 | |
| 0–360 | 57–82 | |
| 0–420 | 68–98 | |
| 0–420 | 84–124 | |
| 0–420 | 102–147 | |
| 0–420 | 120–165 | |
| 0–420 | 126–186 | |
| 0–420 | 136–196 | |
| 0–420 | 160–220 | |
| 0–420 | 168–248 | |
| 0–420 | 170–245 | |
| 0–420 | 200–275 | |
| 0–420 | 210–310 | |
| 0–420 | 240–330 | |
| 0–420 | 252–372 | |
| 0–420 | 280–385 | |
| 0–450 | 24–43 | |
| 0–510 | 22–47 | |
| 0–510 | 28–53 | |
| 0–540 | 27–58 | |
| 0–450 | 48–86 | |
| 0–510 | 44–94 | |
| 0–510 | 56–106 | |
| 0–540 | 54–116 | |
| 0–510 | 66–141 | |
| 0–510 | 84–159 | |
| 0–540 | 81–174 | |
| 0–510 | 88–188 | |
| 0–510 | 112–212 | |
| 0–540 | 108–232 | |
| 0–510 | 140–265 | |
| 0–540 | 135–290 | |
| 0–540 | 160–305 | |
| 0–540 | 162–348 |
Technical sheet
Model 12LM 360/01DR35
Performance curve
The curve covers the range of the supplied table: 0-360 t/h. No data is provided outside this range.
- Table maximum head
- 41m
- Table maximum flow
- 360t/h
- Midpoint
- 35m
At zero flow
6000 l/min· at 29 m
270 t/h ·
4500 l/minat
Table values
| t/h | |||||||
|---|---|---|---|---|---|---|---|
| l/min | |||||||
| Head, m |
Select a number in the table to see the corresponding point.
Points come from the factory table; values between them use linear interpolation. PENTAX · 50 Hz · Source page 443 · 40 · 03/2026
About this product
Description
From the catalogue
Related products
12-inch borehole pumps
PENTAX 12 LMX

Description
PN.ge · PENTAX 12 LMX
Technical tables and curves · 12LM · 50 Hz
Performance curve (Q–H)
Performance table
| Model | Q (t/h) | 0 | 90 | 240 | 270 | 300 | 330 | 360 |
|---|---|---|---|---|---|---|---|---|
| Q (l/min) | 0 | 1500 | 4000 | 4500 | 5000 | 5500 | 6000 | |
| 12LM 360/01DR35 | H (m) | 41 | 40 | 37 | 35 | 33 | 32 | 29 |
Q: flow; H: head at the corresponding flow.
Points come from the factory table; values between them use linear interpolation. PENTAX · Source page 443 · 40 · 03/2026