Series illustration
PENTAX 2 CAB /E
Fully automatic variable speed pressure booster system consisting of 2 pumps, suction manifold with non-return and isolation valves, delivery manifold with pressure gauge and isolation valves, base frame, 2 inverter and 2 pressure sensors. Available on request pressure tanks supplied separately.
Price
on request
Send an inquiry to receive prices and delivery terms within 1–2 days.
Send an inquiryContact us- Official dealer for 20+ brands
- Delivery in Georgia
- 20+ years of experience
Technical tables and curves
PENTAX · 2 CAM / INOX / CAB / ULTRA A / ULTRA SA · 50 Hz
Select a model (3)
Select a model in the table to display its curve and data below.
| Model | Q range (m³/h) | H range (m) |
|---|---|---|
| 0–10.8 | 30.8–61.5 | |
| 0–13.2 | 38.7–62.8 | |
| 0–15.6 | 40.2–68.4 |
Technical sheet
Model 2CABT/E150
Performance curve
The curve covers the range of the supplied table: 0-10.8 t/h. No data is provided outside this range.
- Table maximum head
- 61.5m
- Table maximum flow
- 10.8t/h
- Midpoint
- 48.5m
At zero flow
180 l/min· at 30.8 m
6 t/h ·
100 l/minat
Table values
| t/h | ||||||
|---|---|---|---|---|---|---|
| l/min | ||||||
| Head, m |
Select a number in the table to see the corresponding point.
Points come from the factory table; values between them use linear interpolation. PENTAX · 50 Hz · Source page 220 · 40 · 03/2026
About this product
Description
Self-priming pump booster systems
PENTAX 2 CAB /E

Description
PN.ge · PENTAX 2 CAB /E
Technical tables and curves · 2 CAM / INOX / CAB / ULTRA A / ULTRA SA · 50 Hz
Performance curve (Q–H)
Performance table
| Model | Q (t/h) | 0 | 2.4 | 3.6 | 6 | 8.4 | 10.8 |
|---|---|---|---|---|---|---|---|
| Q (l/min) | 0 | 40 | 60 | 100 | 140 | 180 | |
| 2CABT/E150 | H (m) | 61.5 | 57.2 | 54.7 | 48.5 | 40.9 | 30.8 |
Q: flow; H: head at the corresponding flow.