Series illustration
PENTAX 2 CB /E
Fully automatic variable speed pressure booster system consisting of 2 pumps, suction manifold with non-return and isolation valves, delivery manifold with pressure gauge and isolation valves, base frame, 2 inverter and 2 pressure sensors. Available on request pressure tanks supplied separately.
Price
on request
Send an inquiry to receive prices and delivery terms within 1–2 days.
Send an inquiryContact us- Official dealer for 20+ brands
- Delivery in Georgia
- 20+ years of experience
Technical tables and curves
PENTAX · 2 CM / MB / CB · 50 Hz
Select a model (12)
Select a model in the table to display its curve and data below.
| Model | Q range (m³/h) | H range (m) |
|---|---|---|
| 0–9.6 | 21–42 | |
| 0–14.4 | 31.1–48.3 | |
| 0–16.8 | 32.4–54.9 | |
| 0–18 | 35.2–61.4 | |
| 0–24 | 43.9–63.6 | |
| 0–27 | 53.4–76.9 | |
| 0–30 | 63.7–90.7 | |
| 0–33 | 66.4–97.5 | |
| 0–54 | 38.2–70 | |
| 0–60 | 43.7–80.7 | |
| 0–66 | 45.1–89.5 | |
| 0–66 | 54–98.3 |
Technical sheet
Model 2CBT/E100
Performance curve
The curve covers the range of the supplied table: 0-9.6 t/h. No data is provided outside this range.
- Table maximum head
- 42m
- Table maximum flow
- 9.6t/h
- Midpoint
- 37.4m
At zero flow
160 l/min· at 21 m
3.6 t/h ·
60 l/minat
Table values
| t/h | |||||||
|---|---|---|---|---|---|---|---|
| l/min | |||||||
| Head, m |
Select a number in the table to see the corresponding point.
Points come from the factory table; values between them use linear interpolation. PENTAX · 50 Hz · Source page 223 · 40 · 03/2026
About this product
Description
Centrifugal pump booster systems
PENTAX 2 CB /E

Description
PN.ge · PENTAX 2 CB /E
Technical tables and curves · 2 CM / MB / CB · 50 Hz
Performance curve (Q–H)
Performance table
| Model | Q (t/h) | 0 | 1.2 | 2.4 | 3.6 | 4.8 | 7.2 | 9.6 |
|---|---|---|---|---|---|---|---|---|
| Q (l/min) | 0 | 20 | 40 | 60 | 80 | 120 | 160 | |
| 2CBT/E100 | H (m) | 42 | 40.8 | 39.4 | 37.4 | 34.7 | 29.2 | 21 |
Q: flow; H: head at the corresponding flow.
Points come from the factory table; values between them use linear interpolation. PENTAX · Source page 223 · 40 · 03/2026