Technical tables and curves
PENTAX · 2 / 3 ULTRA V / L / H · 50 Hz
Select a model (37)
Select a model in the table to display its curve and data below.
| Model | Q range (m³/h) | H range (m) |
|---|---|---|
| 0–9.6 | 14–52.2 | |
| 0–9.6 | 18.3–62.8 | |
| 0–9.6 | 25.7–77.1 | |
| 0–9.6 | 26–88.1 | |
| 0–9.6 | 32.2–98.8 | |
| 0–9.6 | 34.5–109.3 | |
| 0–9.6 | 38.3–120.4 | |
| 0–9.6 | 40.8–130.3 | |
| 0–16.8 | 6.4–45.3 | |
| 0–14.4 | 27.4–57.6 | |
| 0–14.4 | 32–69.1 | |
| 0–14.4 | 35.8–80.6 | |
| 0–14.4 | 41.1–92 | |
| 0–14.4 | 45.3–103.3 | |
| 0–14.4 | 50.7–115.1 | |
| 0–14.4 | 57.4–127.6 | |
| 0–14.4 | 66.5–140.3 | |
| 0–16.8 | 28.9–49.6 | |
| 0–16.8 | 39–63.2 | |
| 0–16.8 | 48.2–76 | |
| 0–16.8 | 56.2–89 | |
| 0–16.8 | 62.4–102.3 | |
| 0–16.8 | 73.1–115.2 | |
| 0–16.8 | 83–128.1 | |
| 0–28.8 | 17.9–45.8 | |
| 0–28.8 | 22.3–56.9 | |
| 0–28.8 | 29.6–69.8 | |
| 0–28.8 | 34.7–83.3 | |
| 0–28.8 | 42.1–96.7 | |
| 0–28.8 | 45.2–107.1 | |
| 0–28.8 | 51.2–119.5 | |
| 0–48 | 10.7–34.7 | |
| 0–48 | 17.8–47.1 | |
| 0–48 | 25.3–59.2 | |
| 0–48 | 29.4–71.4 | |
| 0–48 | 41.1–96.1 | |
| 0–48 | 47.8–108.5 |
Technical sheet
Model 3L/I-100/5T-109 / 3L/I-100/5T-306
Performance curve
The curve covers the range of the supplied table: 0-9.6 t/h. No data is provided outside this range.
- Table maximum head
- 52.2m
- Table maximum flow
- 9.6t/h
- Midpoint
- 36m
At zero flow
160 l/min· at 14 m
4.8 t/h ·
80 l/minat
Table values
| t/h | |||||
|---|---|---|---|---|---|
| l/min | |||||
| Head, m |
Select a number in the table to see the corresponding point.
Points come from the factory table; values between them use linear interpolation. PENTAX · 50 Hz · Source page 231 · 40 · 03/2026
About this product
Description
Vertical multistage booster systems
PENTAX 2 ULTRA L /I

Description
PN.ge · PENTAX 2 ULTRA L /I
Technical tables and curves · 2 / 3 ULTRA V / L / H · 50 Hz
Performance curve (Q–H)
Performance table
| Model | Q (t/h) | 0 | 3.6 | 4.8 | 7.2 | 9.6 |
|---|---|---|---|---|---|---|
| Q (l/min) | 0 | 60 | 80 | 120 | 160 | |
| 3L/I-100/5T-109 / 3L/I-100/5T-306 | H (m) | 52.2 | 40.8 | 36 | 25.4 | 14 |
Q: flow; H: head at the corresponding flow.
Points come from the factory table; values between them use linear interpolation. PENTAX · Source page 231 · 40 · 03/2026