Series illustration
PENTAX CM /E S.D.
Plug-and-play pressurization unit consisting of pump, membrane tank, non-return valve, pressure gauge, EPIC inverter and sensor to provide constant pressure in domestic systems regardless of changes in flow demand.
Price
on request
Send an inquiry to receive prices and delivery terms within 1–2 days.
Send an inquiryContact us- Official dealer for 20+ brands
- Delivery in Georgia
- 20+ years of experience
Technical tables and curves
PENTAX · CM · 50 Hz
Select a model (10)
Select a model in the table to display its curve and data below.
| Model | Q range (m³/h) | H range (m) |
|---|---|---|
| 0–4.2 | 8.9–19.3 | |
| 0–5.4 | 12–21.5 | |
| 0–5.4 | 17.5–26.5 | |
| 0–5.4 | 21.5–30 | |
| 0–5.4 | 25.2–33 | |
| 0–6.6 | 27.2–39.4 | |
| 0–7.2 | 35.5–46.3 | |
| 0–7.8 | 39.2–53.2 | |
| 0–18 | 32.5–45.2 | |
| 0–21 | 38.4–54.1 |
Technical sheet
Model CM 45 / CMT 45
Performance curve
The curve covers the range of the supplied table: 0-4.2 t/h. No data is provided outside this range.
- Table maximum head
- 19.3m
- Table maximum flow
- 4.2t/h
- Midpoint
- 15m
At zero flow
70 l/min· at 8.9 m
2.4 t/h ·
40 l/minat
Table values
| t/h | |||||
|---|---|---|---|---|---|
| l/min | |||||
| Head, m |
Select a number in the table to see the corresponding point.
Points come from the factory table; values between them use linear interpolation. PENTAX · 50 Hz · Source page 55 · 40 · 03/2026
About this product
Description
Centrifugal pump booster systems
PENTAX CM /E S.D.

Description
PN.ge · PENTAX CM /E S.D.
Technical tables and curves · CM · 50 Hz
Performance curve (Q–H)
Performance table
| Model | Q (t/h) | 0 | 1.2 | 2.4 | 3.6 | 4.2 |
|---|---|---|---|---|---|---|
| Q (l/min) | 0 | 20 | 40 | 60 | 70 | |
| CM 45 / CMT 45 | H (m) | 19.3 | 17.4 | 15 | 11.3 | 8.9 |
Q: flow; H: head at the corresponding flow.
Points come from the factory table; values between them use linear interpolation. PENTAX · Source page 55 · 40 · 03/2026