Series illustration
PENTAX DV
Drainage pump for charged liquids with set-back Vortex type impeller for civil and industrial applications; specifically designed for very heavy use; available in the mobile or permanent versions with coupling feet.
Price
on request
Send an inquiry to receive prices and delivery terms within 1–2 days.
Send an inquiryContact us- Official dealer for 20+ brands
- Delivery in Georgia
- 20+ years of experience
Technical tables and curves
PENTAX · DV · 50 Hz
Select a model (7)
Select a model in the table to display its curve and data below.
| Model | Q range (m³/h) | H range (m) |
|---|---|---|
| 0–48 | 2.6–12.2 | |
| 0–51 | 3.1–13.7 | |
| 0–54 | 3.8–15.5 | |
| 0–78 | 2.8–21 | |
| 0–90 | 2.6–23.9 | |
| 0–108 | 2.8–24.2 | |
| 0–120 | 2.6–26.7 |
Technical sheet
Model DV 160 / DVT 160
Performance curve
The curve covers the range of the supplied table: 0-48 t/h. No data is provided outside this range.
- Table maximum head
- 12.2m
- Table maximum flow
- 48t/h
- Midpoint
- 5.6m
At zero flow
800 l/min· at 2.6 m
36 t/h ·
600 l/minat
Table values
| t/h | ||||||
|---|---|---|---|---|---|---|
| l/min | ||||||
| Head, m |
Select a number in the table to see the corresponding point.
Points come from the factory table; values between them use linear interpolation. PENTAX · 50 Hz · Source page 275 · 40 · 03/2026
About this product
Description
From the catalogue
Related products
Sewage pumps
PENTAX DV

Description
PN.ge · PENTAX DV
Technical tables and curves · DV · 50 Hz
Performance curve (Q–H)
Performance table
| Model | Q (t/h) | 0 | 12 | 24 | 36 | 42 | 48 |
|---|---|---|---|---|---|---|---|
| Q (l/min) | 0 | 200 | 400 | 600 | 700 | 800 | |
| DV 160 / DVT 160 | H (m) | 12.2 | 10.9 | 8.4 | 5.6 | 4.1 | 2.6 |
Q: flow; H: head at the corresponding flow.
Points come from the factory table; values between them use linear interpolation. PENTAX · Source page 275 · 40 · 03/2026