Series illustration
PENTAX MSH
Multi-stage centrifugal pumps that guarantee high pressure. Particularly suitable for civil and industrial applications - in particular pressurisation systems, fire fighting systems and washing plant.
Price
on request
Send an inquiry to receive prices and delivery terms within 1–2 days.
Send an inquiryContact us- Official dealer for 20+ brands
- Delivery in Georgia
- 20+ years of experience
Technical tables and curves
PENTAX · MSH · 50 Hz
Select a model (22)
Select a model in the table to display its curve and data below.
| Model | Q range (m³/h) | H range (m) |
|---|---|---|
| 0–24 | 43.2–88.2 | |
| 0–24 | 59.7–118 | |
| 0–24 | 73.8–148.2 | |
| 0–24 | 88–177.5 | |
| 0–24 | 119.5–237.8 | |
| 0–39 | 38.6–74.5 | |
| 0–39 | 42.4–101.8 | |
| 0–39 | 59.3–112.7 | |
| 0–39 | 76.2–149.7 | |
| 0–39 | 96.2–187.7 | |
| 0–39 | 115.1–225.9 | |
| 0–57 | 41.8–79.5 | |
| 0–57 | 53–111.9 | |
| 0–57 | 79.2–128.8 | |
| 0–57 | 88.3–159.5 | |
| 0–57 | 130.9–215.7 | |
| 0–57 | 158.9–257.1 | |
| 0–84 | 41–75.9 | |
| 0–84 | 48.5–99.6 | |
| 0–84 | 63–113.9 | |
| 0–84 | 89–152.5 | |
| 0–84 | 112.3–191.4 |
Technical sheet
Model MSHA-3/5,5
Performance curve
The curve covers the range of the supplied table: 0-24 t/h. No data is provided outside this range.
- Table maximum head
- 88.2m
- Table maximum flow
- 24t/h
- Midpoint
- 71.2m
At zero flow
400 l/min· at 43.2 m
15 t/h ·
250 l/minat
Table values
| t/h | ||||||||
|---|---|---|---|---|---|---|---|---|
| l/min | ||||||||
| Head, m |
Select a number in the table to see the corresponding point.
Points come from the factory table; values between them use linear interpolation. PENTAX · 50 Hz · Source page 482 · 40 · 03/2026
About this product
Description
Horizontal multistage pumps
PENTAX MSH

Description
PN.ge · PENTAX MSH
Technical tables and curves · MSH · 50 Hz
Performance curve (Q–H)
Performance table
| Model | Q (t/h) | 0 | 6 | 9 | 12 | 15 | 18 | 21 | 24 |
|---|---|---|---|---|---|---|---|---|---|
| Q (l/min) | 0 | 100 | 150 | 200 | 250 | 300 | 350 | 400 | |
| MSHA-3/5,5 | H (m) | 88.2 | 86.3 | 83.7 | 78.6 | 71.2 | 62.6 | 53.4 | 43.2 |
Q: flow; H: head at the corresponding flow.
Points come from the factory table; values between them use linear interpolation. PENTAX · Source page 482 · 40 · 03/2026