Series illustration
PENTAX PM -BR S.D.
Automatic pressurization unit consisting of pump, membrane tank, pressure switch, pressure gauge, non-return valve and cable with plug. Suitable for pressure boosting in water systems.
Price
on request
Send an inquiry to receive prices and delivery terms within 1–2 days.
Send an inquiryContact us- Official dealer for 20+ brands
- Delivery in Georgia
- 20+ years of experience
Technical tables and curves
PENTAX · PM · 50 Hz
Select a model (1)
Select a model in the table to display its curve and data below.
| Model | Q range (m³/h) | H range (m) |
|---|---|---|
| 0–2.4 | 5–40 |
Technical sheet
Model PM 45BR / PMT 45BR
Performance curve
The curve covers the range of the supplied table: 0-2.4 t/h. No data is provided outside this range.
- Table maximum head
- 40m
- Table maximum flow
- 2.4t/h
- Midpoint
- 21m
At zero flow
40 l/min· at 5 m
1.2 t/h ·
20 l/minat
Table values
| t/h | ||||||
|---|---|---|---|---|---|---|
| l/min | ||||||
| Head, m |
Select a number in the table to see the corresponding point.
Points come from the factory table; values between them use linear interpolation. PENTAX · 50 Hz · Source page 19 · 40 · 03/2026
About this product
Description
From the catalogue
Related products
Peripheral pump booster systems
PENTAX PM -BR S.D.

Description
PN.ge · PENTAX PM -BR S.D.
Technical tables and curves · PM · 50 Hz
Performance curve (Q–H)
Performance table
| Model | Q (t/h) | 0 | 0.3 | 0.6 | 1.2 | 1.8 | 2.4 |
|---|---|---|---|---|---|---|---|
| Q (l/min) | 0 | 5 | 10 | 20 | 30 | 40 | |
| PM 45BR / PMT 45BR | H (m) | 40 | 35 | 30 | 21 | 13 | 5 |
Q: flow; H: head at the corresponding flow.
Points come from the factory table; values between them use linear interpolation. PENTAX · Source page 19 · 40 · 03/2026