
Series illustration
PENTAX ULTRA SA S.D.
Automatic pressurization unit consisting of pump, membrane tank, pressure switch, pressure gauge, non-return valve and cable with plug. Suitable for pressure boosting in water systems.
Price
on request
Send an inquiry to receive prices and delivery terms within 1–2 days.
Send an inquiryContact us- Official dealer for 20+ brands
- Delivery in Georgia
- 20+ years of experience
Technical tables and curves
PENTAX · ULTRA SA · 50 Hz
Select a model (4)
Select a model in the table to display its curve and data below.
| Model | Q range (m³/h) | H range (m) |
|---|---|---|
| 0–4.6 | 13.5–43 | |
| 0–4.6 | 16.8–54 | |
| 0–7.8 | 13.5–44.5 | |
| 0–7.8 | 16.5–56 |
Technical sheet
Model U 3SA-90/4 / U 3SA-90/4T
Performance curve
The curve covers the range of the supplied table: 0-4.6 t/h. No data is provided outside this range.
- Table maximum head
- 43m
- Table maximum flow
- 4.6t/h
- Midpoint
- 35m
At zero flow
76.7 l/min· at 13.5 m
1.8 t/h ·
30 l/minat
Table values
| t/h | |||||||
|---|---|---|---|---|---|---|---|
| l/min | |||||||
| Head, m |
Select a number in the table to see the corresponding point.
Points come from the factory table; values between them use linear interpolation. PENTAX · 50 Hz · Source page 39 · 40 · 03/2026
About this product
Description
Self-priming pump booster systems
PENTAX ULTRA SA S.D.

Description
PN.ge · PENTAX ULTRA SA S.D.
Technical tables and curves · ULTRA SA · 50 Hz
Performance curve (Q–H)
Performance table
| Model | Q (t/h) | 0 | 0.6 | 1.2 | 1.8 | 2.4 | 3.6 | 4.6 |
|---|---|---|---|---|---|---|---|---|
| Q (l/min) | 0 | 10 | 20 | 30 | 40 | 60 | 76.7 | |
| U 3SA-90/4 / U 3SA-90/4T | H (m) | 43 | 41 | 38.3 | 35 | 31.3 | 22.3 | 13.5 |
Q: flow; H: head at the corresponding flow.
Points come from the factory table; values between them use linear interpolation. PENTAX · Source page 39 · 40 · 03/2026


