Series illustration
PENTAX ULTRA SLG /I
Stainless steel multistage vertical pumps. Pumping of clean non-loaded fluids, pressurizing system, irrigation, drinking and glycol water, water treatment, food industry, heating and air conditioning, washing system.
Price
on request
Send an inquiry to receive prices and delivery terms within 1–2 days.
Send an inquiryContact us- Official dealer for 20+ brands
- Delivery in Georgia
- 20+ years of experience
Technical tables and curves
PENTAX · ULTRA SLG-SLXG · 50 Hz
Select a model (18)
Select a model in the table to display its curve and data below.
| Model | Q range (m³/h) | H range (m) |
|---|---|---|
| 0–4.8 | 58.2–154.8 | |
| 0–4.8 | 67–177.5 | |
| 0–4.8 | 75.3–200.3 | |
| 0–4.8 | 81–218.3 | |
| 0–7.2 | 79–159.2 | |
| 0–7.2 | 93.6–182 | |
| 0–7.2 | 103.2–204.4 | |
| 0–7.2 | 114.5–226.7 | |
| 0–9.6 | 87–143.7 | |
| 0–9.6 | 100.3–167.6 | |
| 0–9.6 | 111.1–191.5 | |
| 0–9.6 | 132.3–215.7 | |
| 0–9.6 | 147.7–240.3 | |
| 0–13.2 | 62.7–141.3 | |
| 0–13.2 | 74.6–165.5 | |
| 0–13.2 | 83.9–188.7 | |
| 0–13.2 | 96–213.8 | |
| 0–13.2 | 107–236.7 |
Technical sheet
Model U 3SLG-350/14T
Performance curve
The curve covers the range of the supplied table: 0-4.8 t/h. No data is provided outside this range.
- Table maximum head
- 154.8m
- Table maximum flow
- 4.8t/h
- Midpoint
- 133.7m
At zero flow
80 l/min· at 58.2 m
1.8 t/h ·
30 l/minat
Table values
| t/h | |||||||
|---|---|---|---|---|---|---|---|
| l/min | |||||||
| Head, m |
Select a number in the table to see the corresponding point.
Points come from the factory table; values between them use linear interpolation. PENTAX · 50 Hz · Source page 177 · 40 · 03/2026
About this product
Description
Vertical multistage pumps
PENTAX ULTRA SLG /I

Description
PN.ge · PENTAX ULTRA SLG /I
Technical tables and curves · ULTRA SLG-SLXG · 50 Hz
Performance curve (Q–H)
Performance table
| Model | Q (t/h) | 0 | 0.6 | 1.2 | 1.8 | 2.4 | 3.6 | 4.8 |
|---|---|---|---|---|---|---|---|---|
| Q (l/min) | 0 | 10 | 20 | 30 | 40 | 60 | 80 | |
| U 3SLG-350/14T | H (m) | 154.8 | 150.9 | 143.2 | 133.7 | 122.5 | 94.7 | 58.2 |
Q: flow; H: head at the corresponding flow.
Points come from the factory table; values between them use linear interpolation. PENTAX · Source page 177 · 40 · 03/2026