HMC170-7SV – Vertical pump

HMC170-7SV – Vertical pump

Multistage · 7 stages · 2.4 kW (3.2 HP) · Hmax 87 m · Qmax 10.2 t/h (170 l/min)

Nameplate data

Maximum flow10.2 t/h · 170 l/min
Maximum head92 m
Maximum suction lift9 m
Connection (inlet × outlet)1.25" × 1.25"
Power2.4 kW · 3.2 HP
MotorThree-phase · 380 V · 50 Hz
Rotational speed2850 rpm
Rated current5 A
Insulation classB
Protection classIP44
Operating dutyContinuous

Technical specifications

Select a value to find pumps with the same specification

Pump typeVertical multistage
Maximum flow (Qmax)10.2 t/h · 170 l/min
Maximum head (Hmax)87 m
Power2.4 kW · 3.2 HP
Number of stages7
SKU HMC170-7SV

Price

on request

Send an inquiry to receive prices and delivery terms within 1–2 days.

Send an inquiryContact us
  • Official dealer for 20+ brands
  • Delivery in Georgia
  • 20+ years of experience

Series comparison

The entire series in one table

9 Model in one family, with head at each flow. The model you are viewing is highlighted in dark blue.

HMC

This family
HMC Family performance comparison
Modelt/h →l/min →Curve000.6100.9151.2201.8302.4402.7453503.6604.2704.5754.8805.49061006.31057.21207.81308.11358.714591509.616010.2170
HMC90-5SH1 kW220 V53--514945-413630-2313---------
HMC145-5SH1.5 kWVoltage not confirmed62--605857-555249-464037-2519-7---
HMC90-6SH1.3 kWVoltage not confirmed7069-676460-565043-3627---------
HMC170-6SH2.1 kW380 V75--737170-676561-585550-4237-32282115
HMC145-6SH1.85 kWVoltage not confirmed76--75-73--68--60-49-3527-14---
HMC90-8SV1.65 kW220 V86--807570-655748-3723---------
HMC170-7SVCurrent2.4 kW380 V87--838281-797571-686460-4938-33292620
HMC145-8SV2.5 kW380 V100--979492-878479-746661-4535-20---
HMC-10VE3.7 kWVoltage not confirmed120-116-110-104-95-83-71-5743-30-16--
Table 1. HMC – columns show flow in t/h, with l/min below; cells show head in metres.

Source: manufacturer's technical sheet.Values are for reference. In a real system, pipe diameter, length and bends reduce the available head.

Technical sheet

Model HMC170-7SV

Performance curve

A pump has a performance curve rather than a single flow and head. Qmax and Hmax are at opposite ends and never occur together: at maximum head, flow is zero; at maximum flow, head is zero. Actual operation lies between these extremes.

Hmax 87 mQmax10.2 t/h170 l/min0255075t/h024681012l/min050100150200Head, mFlow
Maximum head
87m

At zero flow

Maximum flow
10.2t/h

170 l/min· at 20 m

Midpoint
64m

5.4 t/h
90 l/minat

Chart 1. Head (m) against flow (t/h, l/min), HMC170-7SV. Blue points show the manufacturer's measured values. Move the pointer near the curve, or touch it on a phone, to read the head and flow at any point.

Measured values

Performance table
t/h
l/min
Head, m

Select a number in the table to see the corresponding point.

HMC170-7SV – Vertical pump · PN.GE