CDL 1-23 – Vertical pump

CDL 1-23 – Vertical pump

1.1 kW (1.5 HP) · Hmax 137 m · Qmax 2 t/h (33 l/min) · DN 25 · 23 stages · AISI 304

Technical specifications

Select a value to find pumps with the same specification

Pump typeMultistage
Maximum flow (Qmax)2 t/h · 33 l/min
Maximum head (Hmax)137 m
Nominal flow1 t/h · 17 l/min
Nominal head128 m
Power1.1 kW · 1.5 HP
Speed2900 rpm
Protection classIP55
Inlet (suction)1" (25 mm)
Outlet (discharge)1" (25 mm)
Maximum fluid temperature120 °C
Casing materialCast iron
Impeller materialStainless steel
Number of stages23
Insulation classF
Frequency50 Hz
SKU CDL-1-23

Price

on request

Send an inquiry to receive prices and delivery terms within 1–2 days.

Send an inquiryContact us
  • Official dealer for 20+ brands
  • Delivery in Georgia
  • 20+ years of experience

Series comparison

The entire series in one table

22 Model in one family, with head at each flow. The model you are viewing is highlighted in dark blue.

CDL 1

Nominal 1 t/h · 17 l/minThis family
CDL 1 Family performance comparison
Modelt/h →l/min →Curve0.46.70.6100.813.3116.71.2201.423.31.626.71.830233.3
CDL 1-20.37 kWVoltage not confirmed1312.51211.51110.5109.59
CDL 1-30.37 kWVoltage not confirmed191817.51716.516151412
CDL 1-40.37 kWVoltage not confirmed2423.52322.521.521191816
CDL 1-50.37 kWVoltage not confirmed3029.629282726242220
CDL 1-60.37 kWVoltage not confirmed3635.53533.53331282623
CDL 1-70.37 kWVoltage not confirmed424140.5393836333027
CDL 1-80.55 kWVoltage not confirmed484746454341383430
CDL 1-90.55 kWVoltage not confirmed545352514946433933
CDL 1-100.55 kWVoltage not confirmed605958575451484336
CDL 1-110.55 kWVoltage not confirmed666563615956524740
CDL 1-120.75 kWVoltage not confirmed727169676461575144
CDL 1-130.75 kWVoltage not confirmed787775736966625547
CDL 1-150.75 kWVoltage not confirmed898886847976716355
CDL 1-171.1 kWVoltage not confirmed1019997958986807162
CDL 1-191.1 kWVoltage not confirmed1131101081069996897969
CDL 1-211.1 kWVoltage not confirmed124122120117110106988775
CDL 1-23Current1.1 kWVoltage not confirmed1371331311281211161079682
CDL 1-251.5 kWVoltage not confirmed14914514313913112611610489
CDL 1-271.5 kWVoltage not confirmed16115715515014113612511295
CDL 1-301.5 kWVoltage not confirmed178175171166157150139124106
CDL 1-332.2 kWVoltage not confirmed196192188183173165154137118
CDL 1-362.2 kWVoltage not confirmed214210205200190181169151130
Table 1. CDL 1 – columns show flow in t/h, with l/min below; cells show head in metres.

Source: manufacturer's technical sheet.Values are for reference. In a real system, pipe diameter, length and bends reduce the available head.

Technical sheet

Model CDL 1-23

Performance curve

A pump has a performance curve rather than a single flow and head. Qmax and Hmax are at opposite ends and never occur together: at maximum head, flow is zero; at maximum flow, head is zero. Actual operation lies between these extremes.

Hmax 137 mQmax2 t/h33.3 l/min050100150t/h00.511.52l/min0102030Head, mFlow
Maximum head
137m

0.4 t/h
6.7 l/minat

Maximum flow
2t/h

33.3 l/min· at 82 m

Midpoint
121m

1.2 t/h
20 l/minat

Chart 1. Head (m) against flow (t/h, l/min), CDL 1-23. Blue points show the manufacturer's measured values. Move the pointer near the curve, or touch it on a phone, to read the head and flow at any point.

Measured values

Performance table
t/h
l/min
Head, m

Select a number in the table to see the corresponding point.

CDL 1-23 – Vertical pump · PN.GE