CDL 8-18 – Vertical pump

CDL 8-18 – Vertical pump

7.5 kW (10 HP) · Hmax 187 m · Qmax 12 t/h (200 l/min) · DN 40 · 18 stages · AISI 304

Technical specifications

Select a value to find pumps with the same specification

Pump typeMultistage
Maximum flow (Qmax)12 t/h · 200 l/min
Maximum head (Hmax)187 m
Nominal flow8 t/h · 133 l/min
Nominal head167 m
Power7.5 kW · 10 HP
Speed2900 rpm
Protection classIP55
Inlet (suction)1½" (40 mm)
Outlet (discharge)1½" (40 mm)
Maximum fluid temperature120 °C
Casing materialCast iron
Impeller materialStainless steel
Number of stages18
Insulation classF
Frequency50 Hz
SKU CDL-8-18

Price

on request

Send an inquiry to receive prices and delivery terms within 1–2 days.

Send an inquiryContact us
  • Official dealer for 20+ brands
  • Delivery in Georgia
  • 20+ years of experience

Series comparison

The entire series in one table

13 Model in one family, with head at each flow. The model you are viewing is highlighted in dark blue.

CDL 8

Nominal 8 t/h · 133 l/minThis family
CDL 8 Family performance comparison
Modelt/h →l/min →Curve583.361007116.78133.3915010166.711183.312200
CDL 8-2-10.75 kWVoltage not confirmed109.59.398.5876
CDL 8-20.75 kWVoltage not confirmed2019.5191817161413
CDL 8-31.1 kWVoltage not confirmed3029.528.52725242119
CDL 8-41.5 kWVoltage not confirmed4139.5383634322826
CDL 8-52.2 kWVoltage not confirmed5250484542403632
CDL 8-62.2 kWVoltage not confirmed6260575451484339
CDL 8-83 kWVoltage not confirmed8380777369655852
CDL 8-104 kWVoltage not confirmed104100979287817365
CDL 8-124 kWVoltage not confirmed124120116111104928778
CDL 8-145.5 kWVoltage not confirmed14514113613012211310292
CDL 8-165.5 kWVoltage not confirmed166161156148139130118106
CDL 8-18Current7.5 kWVoltage not confirmed187182175167157146134120
CDL 8-207.5 kWVoltage not confirmed208202195186175163150135
Table 1. CDL 8 – columns show flow in t/h, with l/min below; cells show head in metres.

Source: manufacturer's technical sheet.Values are for reference. In a real system, pipe diameter, length and bends reduce the available head.

Technical sheet

Model CDL 8-18

Performance curve

A pump has a performance curve rather than a single flow and head. Qmax and Hmax are at opposite ends and never occur together: at maximum head, flow is zero; at maximum flow, head is zero. Actual operation lies between these extremes.

Hmax 187 mQmax12 t/h200 l/min050100150200t/h024681012l/min050100150200Head, mFlow
Maximum head
187m

5 t/h
83.3 l/minat

Maximum flow
12t/h

200 l/min· at 120 m

Midpoint
157m

9 t/h
150 l/minat

Chart 1. Head (m) against flow (t/h, l/min), CDL 8-18. Blue points show the manufacturer's measured values. Move the pointer near the curve, or touch it on a phone, to read the head and flow at any point.

Measured values

Performance table
t/h
l/min
Head, m

Select a number in the table to see the corresponding point.

CDL 8-18 – Vertical pump · PN.GE