CDL 90-40-2 – Vertical pump
30 kW (40 HP) · Hmax 98 m · Qmax 110 t/h (1833 l/min) · DN 100 · 4 stages · AISI 304
Technical specifications
Select a value to find pumps with the same specification
| Pump type | Multistage |
| Maximum flow (Qmax) | 110 t/h · 1833 l/min |
| Maximum head (Hmax) | 98 m |
| Nominal flow | 90 t/h · 1500 l/min |
| Nominal head | 72 m |
| Power | 30 kW · 40.2 HP |
| Speed | 2900 rpm |
| Protection class | IP55 |
| Inlet (suction) | 4" (100 mm) |
| Outlet (discharge) | 4" (100 mm) |
| Maximum fluid temperature | 120 °C |
| Casing material | Cast iron |
| Impeller material | Stainless steel |
| Number of stages | 4 |
| Insulation class | F |
| Frequency | 50 Hz |
Price
on request
Send an inquiry to receive prices and delivery terms within 1–2 days.
Send an inquiryContact us- Official dealer for 20+ brands
- Delivery in Georgia
- 20+ years of experience
Series comparison
The entire series in one table
12 Model in one family, with head at each flow. The model you are viewing is highlighted in dark blue.
CDL 90
Nominal 90 t/h · 1500 l/minThis family| Modelt/h →l/min → | Curve | 50833.3 | 55916.7 | 601000 | 651083.3 | 701166.7 | 801333.3 | 851416.7 | 901500 | 1001666.7 | 1101833.3 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| CDL 90-10-15.5 kWVoltage not confirmed | 22 | 21 | 19 | 18 | 17 | 16 | 14 | 13 | 10 | 6 | |
| CDL 90-107.5 kWVoltage not confirmed | 25 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 16 | 12 | |
| CDL 90-20-211 kWVoltage not confirmed | 41 | 40 | 39 | 38 | 36 | 32 | 30 | 28 | 22 | 15 | |
| CDL 90-2015 kWVoltage not confirmed | 53 | 52 | 50 | 49 | 47 | 44 | 41 | 40 | 36 | 30 | |
| CDL 90-30-218.5 kWVoltage not confirmed | 68 | 67 | 65 | 63 | 60 | 55 | 52 | 49 | 41 | 32 | |
| CDL 90-3022 kWVoltage not confirmed | 81 | 79 | 77 | 75 | 72 | 67 | 64 | 62 | 55 | 48 | |
| CDL 90-40-2Current30 kWVoltage not confirmed | 98 | 96 | 93 | 90 | 87 | 80 | 75 | 72 | 62 | 50 | |
| CDL 90-4030 kWVoltage not confirmed | 110 | 108 | 105 | 103 | 100 | 92 | 86 | 84 | 76 | 66 | |
| CDL 90-50-237 kWVoltage not confirmed | 126 | 123 | 120 | 117 | 113 | 104 | 98 | 93 | 81 | 68 | |
| CDL 90-5037 kWVoltage not confirmed | 139 | 135 | 131 | 128 | 124 | 115 | 110 | 106 | 94 | 83 | |
| CDL 90-60-245 kWVoltage not confirmed | 155 | 152 | 148 | 144 | 139 | 129 | 122 | 117 | 102 | 86 | |
| CDL 90-6045 kWVoltage not confirmed | 168 | 164 | 160 | 155 | 150 | 141 | 134 | 130 | 117 | 103 |
Source: manufacturer's technical sheet.Values are for reference. In a real system, pipe diameter, length and bends reduce the available head.
Technical sheet
Model CDL 90-40-2
Performance curve
A pump has a performance curve rather than a single flow and head. Qmax and Hmax are at opposite ends and never occur together: at maximum head, flow is zero; at maximum flow, head is zero. Actual operation lies between these extremes.
- Maximum head
- 98m
- Maximum flow
- 110t/h
- Midpoint
- 80m
50 t/h ·
833.3 l/minat
1833.3 l/min· at 50 m
80 t/h ·
1333.3 l/minat
Measured values
| t/h | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| l/min | ||||||||||
| Head, m |
Select a number in the table to see the corresponding point.
Vertical stainless steel pumps
CDL 90-40-2 – Vertical pump
30 kW (40 HP) · Hmax 98 m · Qmax 110 t/h (1833 l/min) · DN 100 · 4 stages · AISI 304

Technical specifications
| Pump type | Multistage |
|---|---|
| Maximum flow (Qmax) | 110 t/h · 1833 l/min |
| Maximum head (Hmax) | 98 m |
| Nominal flow | 90 t/h · 1500 l/min |
| Nominal head | 72 m |
| Power | 30 kW · 40.2 HP |
| Speed | 2900 rpm |
| Protection class | IP55 |
| Inlet (suction) | 4" (100 mm) |
| Outlet (discharge) | 4" (100 mm) |
| Maximum fluid temperature | 120 °C |
| Casing material | Cast iron |
| Impeller material | Stainless steel |
| Number of stages | 4 |
| Insulation class | F |
| Frequency | 50 Hz |
Performance curve (Q–H)
Performance table
| Model | Q (t/h) | 50 | 55 | 60 | 65 | 70 | 80 | 85 | 90 | 100 | 110 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| Q (l/min) | 833.3 | 916.7 | 1000 | 1083.3 | 1166.7 | 1333.3 | 1416.7 | 1500 | 1666.7 | 1833.3 | |
| CDL 90-40-2 | H (m) | 98 | 96 | 93 | 90 | 87 | 80 | 75 | 72 | 62 | 50 |
Q: flow; H: head at the corresponding flow. Full CDL 90 series on pn.ge.