Series illustration
Boiler fan YN5-47
Selected model specifications
YN5-47 60W · PNJ2-YN5-47-60-0.06KW-2800RPM
| Catalogue model | YN5-47 60W |
|---|---|
| Power | 0.06 kW |
| Speed | 2800 rpm |
| Flow | 240 m³/h |
| Pressure | 310 Pa |
| Pressure type | Full |
| Voltage | 220/380 V |
| Input power | 60 W |
| Type | High-temperature boiler fans |
Price
on request
Send an inquiry to receive prices and delivery terms within 1–2 days.
Send an inquiryContact us- Official dealer for 20+ brands
- Delivery in Georgia
- 20+ years of experience
Models and technical data
Select a model or its data in the table.
Selected model: YN5-47 60W
| Model | Power (kW) | Speed (rpm) | Flow (m³/h) | Pressure (Pa) |
|---|---|---|---|---|
| 0.06 kW | 2800 rpm | 240 m³/h | 310 Pa | |
| 0.09 kW | 2800 rpm | 350 m³/h | 360 Pa | |
| 0.12 kW | 2800 rpm | 480 m³/h | 450 Pa | |
| 0.18 kW | 2800 rpm | 650 m³/h | 510 Pa | |
| 0.25 kW | 2800 rpm | 860 m³/h | 580 Pa | |
| 0.37 kW | 2800 rpm | 1100 m³/h | 650 Pa | |
| 0.55 kW | 2800 rpm | 1450 m³/h | 680 Pa | |
| 0.75 kW | 2800 rpm | 1810 m³/h | 790 Pa | |
| 1.1 kW | 2800 rpm | 2250 m³/h | 940 Pa | |
| 1.5 kW | 2800 rpm | 2800 m³/h | 1140 Pa | |
| 2.2 kW | 2800 rpm | 3100 m³/h | 1280 Pa |
Scroll sideways or down to view the full table.
Airflow performance curve
YN5-47 60W
Calculated curve · Total pressure · 2800 rpm
Calculated value – approximate
Calculated points (approximate)
| Q (m³/h) | Total pressure (Pa) |
|---|---|
| ≈ 298 | |
| ≈ 263 | |
| ≈ 208 | |
| ≈ 130 | |
| ≈ 30 |
Catalogue Q/Pa ratings set the scale of the calculated graph only. Their pairing as a single duty point is unconfirmed; the curve shape and all points are provisional.
Basis: Model catalogue ratings and provisional calculated shapeQ: 240 m³/h; Pressure: 310 Pa
High-temperature boiler fans
Boiler fan YN5-47
Selected model: YN5-47 60W
SKU PNJ2-YN5-47-60-0.06KW-2800RPM

Selected model specifications
| Catalogue model | YN5-47 60W |
|---|---|
| Power | 0.06 kW |
| Speed | 2800 rpm |
| Flow | 240 m³/h |
| Pressure | 310 Pa |
| Pressure type | Full |
| Voltage | 220/380 V |
| Input power | 60 W |
| Type | High-temperature boiler fans |
Airflow performance curve
YN5-47 60W
Calculated curve · Total pressure · 2800 rpm
Calculated points (approximate)
| Q (m³/h) | Total pressure (Pa) |
|---|---|
| 48 | ≈ 298 |
| 93 | ≈ 263 |
| 138 | ≈ 208 |
| 183 | ≈ 130 |
| 228 | ≈ 30 |
Catalogue Q/Pa ratings set the scale of the calculated graph only. Their pairing as a single duty point is unconfirmed; the curve shape and all points are provisional.
Basis: Model catalogue ratings and provisional calculated shapeQ: 240 m³/h; Pressure: 310 Pa
Model catalogue data
| Model | Power (kW) | Speed (rpm) | Flow (m³/h) | Pressure (Pa) |
|---|---|---|---|---|
| YN5-47 60W | 0.06 kW | 2800 rpm | 240 m³/h | 310 Pa |