FTD40-20G2 – Circulation pump
2.2 kW · Hmax 22 m
Nameplate data
| Maximum head | 22 m |
|---|---|
| Nominal flow | 12.5 t/h · 208.33 l/min |
| Nominal head | 20 m |
| Maximum water temperature | 100 °C |
| Maximum suction lift | 7 m |
| Connection (inlet × outlet) | 40 × 40 mm |
| Power | 2.2 kW · 3 HP |
|---|---|
| Motor | Three-phase · 380 V · 50 Hz |
| Rotational speed | 2900 rpm |
| Insulation class | F |
| Protection class | IP54 |
| Operating duty | Continuous |
Technical specifications
Select a value to find pumps with the same specification
| Pump type | Circulation |
| Maximum head (Hmax) | 22 m |
| Nominal flow | 12.5 t/h · 208 l/min |
| Nominal head | 20 m |
| Power | 2.2 kW · 2.9 HP |
| Voltage / phase | 3 phase – 380V |
| Speed | 2900 rpm |
| Protection class | IP54 |
| Inlet (suction) | 1½" (40 mm) |
| Outlet (discharge) | 1½" (40 mm) |
| Maximum fluid temperature | 100 °C |
| Insulation class | F |
| Frequency | 50 Hz |
Price
on request
Send an inquiry to receive prices and delivery terms within 1–2 days.
Send an inquiryContact us- Official dealer for 20+ brands
- Delivery in Georgia
- 20+ years of experience
Manufacturer's tables
Technical data
Motor connection – nameplate data
| Connection | Voltage | Current |
|---|---|---|
| Δ | 220 V | 8.2 A |
| Y | 380 V | 4.7 A |
FTD – performance table
The 8 models in the supplied table. Select a row to open a model; the current model is highlighted in blue.
| Model | DN (mm) | kW | Q (t/h) | 0 | 2 | 5 | 8 | 10 | 12.5 | 16 | 20 | 25 | 30 | 35 | 40 | 45 | 50 | 60 | 70 | 80 | 90 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Q (l/min) | 0 | 33 | 83 | 133 | 167 | 208 | 267 | 333 | 417 | 500 | 583 | 667 | 750 | 833 | 1000 | 1167 | 1333 | 1500 | |||
| FTD40-16G2 | 40 × 40 | 1.1 | H (m) | 19.8 | 19.8 | 18.9 | 18.2 | 17.5 | 16 | 11.4 | — | — | — | — | — | — | — | — | — | — | — |
| FTD40-20G2 | 40 × 40 | 2.2 | H (m) | 23 | 23 | 22.7 | 22.5 | 22.2 | 22 | 21.3 | 20 | 16.6 | — | — | — | — | — | — | — | — | — |
| FTD50-15G2 | 50 × 50 | 1.5 | H (m) | 16.1 | — | 16.1 | 16.1 | 16.1 | 15.9 | 15.6 | 15 | 13.3 | — | — | — | — | — | — | — | — | — |
| FTD50-18G2 | 50 × 50 | 2.2 | H (m) | 20.2 | — | 20.2 | 20.1 | 20 | 19.9 | 19.6 | 19 | 18 | 16.4 | — | — | — | — | — | — | — | — |
| FTD50-28G2 | 50 × 50 | 4 | H (m) | 29.5 | — | 29.5 | 29.5 | 29.5 | 29.5 | 29.3 | 29.2 | 28.8 | 28 | 26.4 | — | — | — | — | — | — | — |
| FTD65-15G2 | 65 × 65 | 2.2 | H (m) | 17.7 | — | — | — | 17.1 | 16.9 | 16.7 | 16.4 | 15.7 | 15 | 13.2 | 11.3 | — | — | — | — | — | — |
| FTD65-20G2 | 65 × 65 | 3 | H (m) | 22 | — | — | — | 21.8 | 21.6 | 21.4 | 21.2 | 20.6 | 20 | 18.7 | 17.4 | — | — | — | — | — | — |
| FTD80-23G2 | 80 × 80 | 5.5 | H (m) | 28.2 | — | — | — | 28.2 | 28.2 | 28.1 | 28 | 27.5 | 27 | 26.1 | 25.2 | 24.1 | 23 | 19.5 | 13.9 | 7.1 | — |
Source: supplied FTD performance table. “—” means the source provides no value. The source rounds l/min values; curve flow is converted from t/h.
The supplied performance table gives H=23 m at Q=0; the nameplate states Hmax=22 m. Nameplate data is shown separately; the curve uses the supplied table.
Technical sheet
Model FTD40-20G2
Performance curve
The curve covers the range of the supplied table: 0-25 t/h. No data is provided outside this range.
- Table maximum head
- 23m
- Table maximum flow
- 25t/h
- Midpoint
- 22.2m
At zero flow
416.67 l/min· at 16.6 m
10 t/h ·
166.67 l/minat
Circulation pumps
FTD40-20G2 – Circulation pump
2.2 kW · Hmax 22 m

Nameplate data
| Maximum head | 22 m |
|---|---|
| Nominal flow | 12.5 t/h · 208.33 l/min |
| Nominal head | 20 m |
| Maximum water temperature | 100 °C |
| Maximum suction lift | 7 m |
| Connection (inlet × outlet) | 40 × 40 mm |
| Power | 2.2 kW · 3 HP |
| Motor | Three-phase · 380 V · 50 Hz |
| Rotational speed | 2900 rpm |
| Insulation class | F |
| Protection class | IP54 |
| Operating duty | Continuous |
Technical specifications
| Pump type | Circulation |
|---|---|
| Maximum head (Hmax) | 22 m |
| Nominal flow | 12.5 t/h · 208 l/min |
| Nominal head | 20 m |
| Inlet (suction) | 1½" (40 mm) |
| Outlet (discharge) | 1½" (40 mm) |
| Maximum fluid temperature | 100 °C |
Performance curve (Q–H)
Performance table
| Model | Q (t/h) | 0 | 2 | 5 | 8 | 10 | 12.5 | 16 | 20 | 25 |
|---|---|---|---|---|---|---|---|---|---|---|
| Q (l/min) | 0 | 33 | 83 | 133 | 167 | 208 | 267 | 333 | 417 | |
| FTD40-20G2 | H (m) | 23 | 23 | 22.7 | 22.5 | 22.2 | 22 | 21.3 | 20 | 16.6 |
Q: flow; H: head at the corresponding flow. The source rounds l/min values. Full FTD series on pn.ge.
The supplied performance table gives H=23 m at Q=0; the nameplate states Hmax=22 m. Nameplate data is shown separately; the curve uses the supplied table.
Motor connection – nameplate data
| Connection | Voltage | Current |
|---|---|---|
| Δ | 220 V | 8.2 A |
| Y | 380 V | 4.7 A |