FTD65-15G2 – Circulation pump
Technical specifications
Select a value to find pumps with the same specification
| Pump type | Circulation |
| Power | 2.2 kW · 2.9 HP |
| Inlet (suction) | 2½" (65 mm) |
| Outlet (discharge) | 2½" (65 mm) |
Price
on request
Send an inquiry to receive prices and delivery terms within 1–2 days.
Send an inquiryContact us- Official dealer for 20+ brands
- Delivery in Georgia
- 20+ years of experience
FTD – performance table
The 8 models in the supplied table. Select a row to open a model; the current model is highlighted in blue.
| Model | DN (mm) | kW | Q (t/h) | 0 | 2 | 5 | 8 | 10 | 12.5 | 16 | 20 | 25 | 30 | 35 | 40 | 45 | 50 | 60 | 70 | 80 | 90 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Q (l/min) | 0 | 33 | 83 | 133 | 167 | 208 | 267 | 333 | 417 | 500 | 583 | 667 | 750 | 833 | 1000 | 1167 | 1333 | 1500 | |||
| FTD40-16G2 | 40 × 40 | 1.1 | H (m) | 19.8 | 19.8 | 18.9 | 18.2 | 17.5 | 16 | 11.4 | — | — | — | — | — | — | — | — | — | — | — |
| FTD40-20G2 | 40 × 40 | 2.2 | H (m) | 23 | 23 | 22.7 | 22.5 | 22.2 | 22 | 21.3 | 20 | 16.6 | — | — | — | — | — | — | — | — | — |
| FTD50-15G2 | 50 × 50 | 1.5 | H (m) | 16.1 | — | 16.1 | 16.1 | 16.1 | 15.9 | 15.6 | 15 | 13.3 | — | — | — | — | — | — | — | — | — |
| FTD50-18G2 | 50 × 50 | 2.2 | H (m) | 20.2 | — | 20.2 | 20.1 | 20 | 19.9 | 19.6 | 19 | 18 | 16.4 | — | — | — | — | — | — | — | — |
| FTD50-28G2 | 50 × 50 | 4 | H (m) | 29.5 | — | 29.5 | 29.5 | 29.5 | 29.5 | 29.3 | 29.2 | 28.8 | 28 | 26.4 | — | — | — | — | — | — | — |
| FTD65-15G2 | 65 × 65 | 2.2 | H (m) | 17.7 | — | — | — | 17.1 | 16.9 | 16.7 | 16.4 | 15.7 | 15 | 13.2 | 11.3 | — | — | — | — | — | — |
| FTD65-20G2 | 65 × 65 | 3 | H (m) | 22 | — | — | — | 21.8 | 21.6 | 21.4 | 21.2 | 20.6 | 20 | 18.7 | 17.4 | — | — | — | — | — | — |
| FTD80-23G2 | 80 × 80 | 5.5 | H (m) | 28.2 | — | — | — | 28.2 | 28.2 | 28.1 | 28 | 27.5 | 27 | 26.1 | 25.2 | 24.1 | 23 | 19.5 | 13.9 | 7.1 | — |
Source: supplied FTD performance table. “—” means the source provides no value. The source rounds l/min values; curve flow is converted from t/h.
The curve uses the supplied performance table. Nameplate data is shown separately.
Technical sheet
Model FTD65-15G2
Performance curve
The curve covers the range of the supplied table: 0-40 t/h. No data is provided outside this range.
- Table maximum head
- 17.7m
- Table maximum flow
- 40t/h
- Midpoint
- 16.4m
At zero flow
666.67 l/min· at 11.3 m
20 t/h ·
333.33 l/minat
Circulation pumps
FTD65-15G2 – Circulation pump

Technical specifications
| Pump type | Circulation |
|---|---|
| Power | 2.2 kW · 2.9 HP |
| Inlet (suction) | 2½" (65 mm) |
| Outlet (discharge) | 2½" (65 mm) |
Performance curve (Q–H)
Performance table
| Model | Q (t/h) | 0 | 10 | 12.5 | 16 | 20 | 25 | 30 | 35 | 40 |
|---|---|---|---|---|---|---|---|---|---|---|
| Q (l/min) | 0 | 167 | 208 | 267 | 333 | 417 | 500 | 583 | 667 | |
| FTD65-15G2 | H (m) | 17.7 | 17.1 | 16.9 | 16.7 | 16.4 | 15.7 | 15 | 13.2 | 11.3 |
Q: flow; H: head at the corresponding flow. The source rounds l/min values. Full FTD series on pn.ge.
The curve uses the supplied performance table. Nameplate data is shown separately.