FE PETRO DEF-STP — AdBlue submersible pump kit – series illustration

Series illustration

FE PETRO DEF-STP — AdBlue submersible pump kit

The FE PETRO DEF-STP kit includes an AdBlue submersible motor assembly, adjustable column pipe, check valve, bypass and EZ FIT connection. VL1 and VL2 differ in length; 50/60 Hz and single-/three-phase configurations are separate. Read more →

Model code (SKU)PN-FF-403469901
Model
403469901
Factory order code
403469901
brands
FE PETRO / Franklin Electric
Frequency
60 Hz
Phases
Single-phase
Model length
1,750 mm - 2,590 mm

Price

on request

Send an inquiry to receive prices and delivery terms within 1–2 days.

Send an inquiryContact us
  • Official dealer for 20+ brands
  • Delivery in Georgia
  • 20+ years of experience

Select a model by clicking its data in the table.

Compare models

ModelFrequencyModel length
60 Hz1,750 mm - 2,590 mm
60 Hz2,590 mm - 4,215 mm
60 Hz1,750 mm - 2,590 mm
60 Hz2,590 mm - 4,215 mm
50 Hz1,800 mm - 2,640 mm
50 Hz2,640 mm - 4,265 mm
50 Hz1,800 mm - 2,640 mm
50 Hz2,640 mm - 4,265 mm

Construction, operation and model selection

Detailed description and use

System application and installation

Installed, grouped and component views

DEF pump in the tank: typical arrangement
Complete kit and fixed-length assembly

DEF pump in the tank: typical arrangement

The PMA hangs vertically from the column pipe and must be completely submerged. The manual’s typical bottom clearance is 3″ (76 mm); never suspend or lift it by its power cable. The bypass provides the minimum circulation required for motor cooling. The drawing identifies the check valve, bypass, gauge connection and dispenser outlet separately.

Flow direction and materials

The DEF check-valve arrow points upward from the PMA towards the outlet. The bypass discharge must not strike the power cable. Use DEF-compatible sealing material; the PMA replacement guide excludes PTFE tape. An optional Thermal Relief kit addresses thermal expansion and does not replace the required bypass relief valve.

Selecting the DEF-PMA electrical execution

DEF-PMA150A is single-phase 60 Hz; the guide specifies a 25 µF capacitor rated at least 370 V. DEF-PMA150B is single-phase 50 Hz with 30 µF, at least 440 V. C and D are three-phase and do not use that capacitor. Controller compatibility is separate: the guide addresses Guardian with firmware 3.8 or later in DEF mode; not every STP controller supports DEF.

Replacement part within the assembly

Use the exploded-view position to identify the exact part code; the context image shows where it works in the pump or control enclosure. Replacement checks code, sealing, dimensions and electrical rating. Avoid damaging new seals, wires or cables during assembly, then verify the relevant pressure or electrical function.

Full installation manuals and drawings

Consult the specific model’s factory manual for the complete installation/service sequence, connections and safety requirements.

DEF / AdBlue fluid and application

These pumps handle DEF/AdBlue, the ISO 22241-1 AUS32 solution of 32.5% urea in distilled/deionized water. DEF is not diesel fuel. The catalogue lists specific gravity 1.09 at 20°C. Stainless wetted parts and compatible elastomers help avoid contamination of the solution.

Complete kit and fixed-length assembly

A variable-length DEF STP kit contains the VL1/VL2 column-pipe kit, check-valve kit, bypass, EZ FIT PMA connection and the selected single/three-phase PMA. Fixed-length assemblies use locally supplied 2″ NPT column pipe and separately ordered subkits. Stainless hardware and Viton/EPDM seals suit DEF.

PMA motor and hydraulic assembly

DEF PMA has a 130 mm (5.1″) outside diameter. A stainless encapsulated motor, heavy-duty shaft and double mechanical seals separate the fluid from the oil-filled bearing chamber. Impellers, diffusers and connections are stainless. For vertical installation, discharge piping suspends the assembly clear of the tank bottom.

50/60 Hz hydraulics, cooling and valves

60 Hz models are two-stage with a 2″ NPT female outlet; 50 Hz models are three-stage with 2″ BSPT. Product flow cools the continuously rated motor. Required bypass opening pressure is 30–40 psi (2.1–2.8 bar), with minimum flow 4 gpm (about 15 L/min). Check-valve maximum cracking pressure is 3 psi (0.2 bar).

Cable execution and document version

The PMA webpage lists a 7 m plug-in cable with polyethylene jacket, while the revised document and complete-kit page specify a 10 m EPDM cable. These are differing source executions, not a promise that both cables are included. Confirm cable length and jacket against the current document for the ordered configuration.

Factory photos and details

Select an image to enlarge

DEF / AdBlue fluid and application
PMA motor and hydraulic assembly
Complete kit and fixed-length assembly
50/60 Hz hydraulics, cooling and valvesDEF STP - Performance
DEF pump in the tank: typical arrangement

Descriptions include series-wide and optional features. Check the selected model’s table and documents for its actual configuration.

Original description and contents — 403469901

Manufacturer data (English)

Variable Length Diesel Exhaust Fluid Submersible Turbine Pump Kits - 60Hz

Model Number403469901
Description60 Hz, single phase, VL1 69" - 102" (1,750 mm - 2,590 mm) variable length diesel exhaust fluid submersible turbine pump kits (includes components #1 - #5)
Series data and documents — Manufacturer data (English)

Materials: Stainless steel construction including impellers/diffusers, inlet/outlet, and outer shell

Pump type: All models are 5.1" (130 mm) outside diameter centrifugal type pump

Power cable: 32.8' (10 m) EPDM jacketed power cable

60 Hz pump motor: Two-stage pump with 2" NPT female outlet

50 Hz pump motor: Three-stage pump with 2" BSPT female outlet

Motor rating: Continuous operation with motor cooling provided by product flow and protected from dry running

All stainless steel hardware and Viton® or EPDM seals

Bypass relief valve cracking pressure of 30-40 psi (2.1-2.8 bar) and 4 gpm (15 lpm) minimum flow at the discharge of all models

Non-return check valve cracking pressure of 3 psi (0.2 bar) between product piping and bypass relief valve of all models

Liquid compatibility: All models are intended for use with Diesel Exhaust Fluid (DEF). DEF is a non-flammable, non-combustible liquid that has a specific gravity of 1.09 at 68˚F (20˚C), and is made per ISO 22241-1 specifications with 32.5% urea and distilled or deionized water. As defined by ISO 22241-1, DEF is the same as AUS 32® (aqueous urea solution) and also commonly known as AdBlue®

Each variable length submersible turbine pump kit comes complete with variable length column pipe kit (VL1 or VL2), check valve kit, bypass kit, EZ FIT pump motor assembly connection kit, and pump motor assembly (single or three phase).

Variable length column pipe kit, 2" to 1½" NPT (not sold separately)

Check valve kit

Bypass kit

Pump motor assembly connection kit

Pump motor assembly (single or three phase)

Individual assembly kits can be ordered for fixed length submersible turbine pump kit applications.

Column pipe, 2" NPT (locally supplied)

Check valve kit

Bypass kit

Pump motor assembly connection kit

Pump motor assembly (single or three phase)

Variable Length Diesel Exhaust Fluid Submersible Turbine Pump Kits - 60Hz

Model NumberDescription
40346990160 Hz, single phase, VL1 69" - 102" (1,750 mm - 2,590 mm) variable length diesel exhaust fluid submersible turbine pump kits (includes components #1 - #5)
40347090160 Hz, single phase, VL2 102" - 166" (2,590 mm - 4,215 mm) variable length diesel exhaust fluid submersible turbine pump kits (includes components #1 - #5)
40347890160 Hz, three phase, VL1 69" - 102" (1,750 mm - 2,590 mm) variable length diesel exhaust fluid submersible turbine pump kits (includes components #1 - #4 and #6)
40347990160 Hz, three phase, VL2 102" - 166" (2,590 mm - 4,215 mm) variable length diesel exhaust fluid submersible turbine pump kits (includes components #1 - #4 and #6)

Variable Length Diesel Exhaust Fluid Submersible Turbine Pump Kits - 50Hz

Model NumberDescription
40347290150 Hz, single phase, VL1 71" - 104" (1,800 mm - 2,640 mm) variable length diesel exhaust fluid submersible turbine pump kits (includes components #1 - #5)
40347390150 Hz, single phase, VL2 104" - 168" (2,640 mm - 4,265 mm) variable length diesel exhaust fluid submersible turbine pump kits (includes components #1 - #5)
40347590150 Hz, three phase, VL1 71" - 104" (1,800 mm - 2,640 mm) variable length diesel exhaust fluid submersible turbine pump kits (includes components #1 - #4 and #6)
40347690150 Hz, three phase, VL2 104" - 168" (2,640 mm - 4,265 mm) variable length diesel exhaust fluid submersible turbine pump kits (includes components #1 - #4 and #6)

Variable Length Diesel Exhaust Fluid Submersible Turbine Pump Replacement Kits - 60Hz

Model NumberDescription
40338390360 Hz, single phase pump motor assembly (DEF-PMA150A)
40338393360 Hz, three phase pump motor assembly (DEF-PMA150D)
403454901Pump motor assembly connection kit (includes 2" NPT male inlet x 1½" NPT male outlet EZ FIT connection
403461901Bypass kit (includes ½" NPT bypass relief valve, ½" NPT x 1½" NPT bushing in 1½" NPT tee)
403463901Check valve kit (includes 1½" NPT non-return check valve, 1½" NPT x 4" long nipple on inlet, and 2" NPT female x 2" BSP male Adapter on outlet)

Variable Length Diesel Exhaust Fluid Submersible Turbine Pump Replacement Kits - 50Hz

Model NumberDescription
40338395350 Hz, single phase pump motor assembly (DEF-PMA150B)
40338396350 Hz, three phase pump motor assembly (DEF-PMA150C)
403455901Pump motor assembly connection kit (includes 2" BSP male inlet x 1½" NPT male outlet EZ FIT connection
403461901Bypass kit (includes ½" NPT bypass relief valve, ½" NPT x 1½" NPT bushing in 1½" NPT tee)
403463901Check valve kit (includes 1½" NPT non-return check valve, 1½" NPT x 4" long nipple on inlet, and 2" NPT female x 2" BSP male Adapter on outlet)

Variable Length Accessories & Repair Parts - 60Hz

Model NumberDescription
400170936Capacitor, 25 uF / 370 V (for use with DEF-PMA150A)
400818921STP-CBS, single-phase control box, with switch and lockout, 120 Volt coil
401220903STP-CB3 three-phase control box, 120 Volt relay, 3 hp, 208-230 Volt, 60 Hz pump control
4034089311½" NPT non-return check valve (part of component #2, valve only)
403409931½" NPT bypass relief valve (part of component #3 , valve only)
403468901DEF-PMA hardware pack (part of components #5 or #6, includes cable grip, cable ties, and documentation)

Variable Length Accessories & Repair Parts - 50Hz

Model NumberDescription
400170937Capacitor, 30 uF / 440 V (for use with DEF-PMA150B)
400818922STP-CBBS, single-phase control box, with switch and lockout, 240 Volt coil
401220966STP-CBB5C three phase control box, 5hp 380-415 Volt pump control
4034089311½" NPT non-return check valve (part of component #2, valve only)
403409931½" NPT bypass relief valve (part of component #3 , valve only)
4034599012" NPT female x 2" BSP male thread Adapter (part of component #1, Adapter only)
403468901DEF-PMA hardware pack (part of components #5 or #6, includes cable grip, cable ties, and documentation)

Fixed Length Diesel Exhaust Fluid Submersible Turbine Pump Kits - 60Hz

Model NumberDescription
40338390360 Hz, single phase pump motor assembly (DEF-PMA150A)
40338393360 Hz, three phase pump motor assembly (DEF-PMA150D)
403456901Pump motor assembly connection kit (includes 2" NPT male inlet x 2" NPT male outlet EZ FIT connection
403462901Bypass kit (includes ½" NPT bypass relief valve, ½" NPT x 2" NPT bushing in 2" NPT tee)
403464901Check valve kit (includes 2" NPT non-return check valve and 2" NPT x 4" long nipple on inlet)

Fixed Length Diesel Exhaust Fluid Submersible Turbine Pump Kits - 50Hz

Model NumberDescription
40338395350 Hz, single phase pump motor assembly (DEF-PMA150B)
40338396350 Hz, three phase pump motor assembly (DEF-PMA150C)
403457901Pump motor assembly connection kit (includes 2" BSP male inlet x 2" NPT male outlet EZ FIT connection
403462901Bypass kit (includes ½" NPT bypass relief valve, ½" NPT x 2" NPT bushing in 2" NPT tee)
403465901Check valve kit (includes 2" NPT non-return check valve, 2" NPT x 4" long nipple on inlet, and 2" NPT male x 2 " BSP female Adapter on outlet)

Fixed Length Accessories & Repair Parts - 60Hz

Model NumberDescription
400170936Capacitor, 25 uF / 370 V (for use with DEF-PMA150A)
400818921STP-CBS, single-phase control box, with switch and lockout, 120 Volt coil
401220903STP-CB3 three-phase control box, 120 Volt relay, 3 hp, 208-230 Volt, 60 Hz pump control
4034089322" NPT non-return check valve (part of component #2, valve only)
403409931½" NPT bypass relief valve (part of component #3 , valve only)
403468901DEF-PMA hardware pack (part of components #5 or #6, includes cable grip, cable ties, and documentation)

Fixed Length Accessories & Repair Parts - 50Hz

Model NumberDescription
400170937Capacitor, 30 uF / 440 V (for use with DEF-PMA150B)
400818922STP-CBBS, single-phase control box, with switch and lockout, 240 Volt coil
401220966STP-CBB5C three phase control box, 5hp 380-415 Volt pump control
4034089322" NPT non-return check valve (part of component #2, valve only)
403409931½" NPT bypass relief valve (part of component #3 , valve only)
4034589012" NPT x 4" long Pipe Nipple (part of component #2, nipple only)
4034609012" NPT Male x 2" BSP Female Thread Adapter (part of component #2, Adapter only)
403468901DEF-PMA hardware pack (part of components #5 or #6, includes cable grip, cable ties, and documentation)
Source page ↗ Franklin Electric Fueling Systems

About this product

Description

The FE PETRO DEF-STP kit includes an AdBlue submersible motor assembly, adjustable column pipe, check valve, bypass and EZ FIT connection. VL1 and VL2 differ in length; 50/60 Hz and single-/three-phase configurations are separate. Fixed-length assembly components are listed under DEF service parts with their factory order codes.