FE PETRO 6″ — high-capacity fuel pump – series illustration

Series illustration

FE PETRO 6″ — high-capacity fuel pump

The FE PETRO 6″ submersible turbine pump serves high-volume fuel delivery. The range covers 3 Hp and 5 Hp three-phase configurations; the ordering table separates 50 and 60 Hz versions. Read more →

Model code (SKU)PN-FF-401004901
Model
401004901
Factory order code
401004901
brands
FE PETRO / Franklin Electric
Power
3 Hp
Frequency
60 Hz
Phases
Three-phase
Nominal supply
208-230 VAC

Price

on request

Send an inquiry to receive prices and delivery terms within 1–2 days.

Send an inquiryContact us
  • Official dealer for 20+ brands
  • Delivery in Georgia
  • 20+ years of experience

Select a model by clicking its data in the table.

Compare models

ModelPowerFrequency
3 Hp60 Hz
5 Hp60 Hz
5 Hp60 Hz
5 Hp50 Hz
3 Hp50 Hz
Factory performance curve — 60 Hz
Factory performance curve — 60 Hz

This curve applies to the stated frequency and configuration. For 50 Hz use the corresponding document.

Construction, operation and model selection

Detailed description and use

System application and installation

Installed, grouped and component views

High-capacity pump in an installation
Two tanks: syphon versus delivery manifold
Why several pumps are manifolded

High-capacity pump in an installation

The 6″ riser supports the pump on the tank, with motor and hydraulics submerged and delivery lines connected to the upper manifold. The drawing locates the manifold, PMA, electrical conduit and intake. Its extractable design supports servicing without dismantling all delivery piping. Final length depends on tank depth and burial geometry.

Two tanks: syphon versus delivery manifold

A syphon transfers product between tanks containing the same fuel; a pressurized manifold combines pump delivery lines. The high-capacity installation guide illustrates both arrangements. Tank levels, vacuum pickup and valve positions serve different functions, so the two layouts are not interchangeable.

Why several pumps are manifolded

Manifolded pumps feed a shared delivery line. A correctly selected system can stage another pump as demand rises, distribute duty and provide service redundancy. Combined output depends on the individual pump curves, piping resistance and control mode; pump count alone does not determine the final flow.

Commissioning and servicing

Installation includes electrical isolation/lockout, grounding checks and fuel-compatible sealing. After connecting the hydraulics, commissioning removes air and checks pressure, leaks and the applicable protection functions. Replacement extractable parts must match their factory codes. The linked manual provides the complete procedure and configuration-specific electrical diagram.

Full installation manuals and drawings

Consult the specific model’s factory manual for the complete installation/service sequence, connections and safety requirements.

3/5 Hp high-capacity construction

A multistage centrifugal pump couples to a three-phase Franklin motor and mounts through a 6″ riser. Construction uses acetal impellers, hard-coated aluminium diffusers and a stainless shaft, with carbon bearings, stainless journals and automatic thermal protection. Assembly length is selected for the tank and burial depth.

Pressure protection and service construction

Two opposing 3″ horizontal outlets are arranged 180° apart. Two line check valves and two relief valves address thermal-expansion pressure; an inlet screen excludes large debris. The extractable assembly has automatic electrical disconnect contacts and lifting eyes, while four bolts attach the PMA to the head.

50 Hz and 60 Hz executions

50 Hz executions use three-phase 380–415 VAC, 3/5 Hp and fixed 2875 rpm. The 60 Hz class uses three-phase 208–230, 460 or 575 VAC, 3/5 Hp and 3450 rpm; 60 Hz pumps are two-stage. Each execution requires matching control and curves. STPAG supports blends up to E85; standard executions have different approvals.

Fuel blends and execution selection

Standard STP and Alcohol Grade STPAG/STPAP/IST/ISTAP have different blend approvals. The catalogue distinguishes E10/B5 standard equipment from applicable E85 and B20/B100 executions. It also lists 20% MTBE/ETBE or 17% TAME and fluorocarbon elastomers. Maximum viscosity is 70 SSU at 15°C. Confirm final compatibility against the exact order code.

Factory photos and details

Select an image to enlarge

3/5 Hp high-capacity construction
Pressure protection and service construction
Pressure protection and service construction
Factory ordering and assembly diagram
High-capacity pump in an installation
Two tanks: syphon versus delivery manifold
Why several pumps are manifolded

Descriptions include series-wide and optional features. Check the selected model’s table and documents for its actual configuration.

Original description and contents — 401004901

Manufacturer data (English)

High Capacity Turbine Pumps - 60Hz

Model Number401004901
DescriptionSubmersible turbine pump 3 Hp 6", three-phase 208-230 VAC, 00" riser.
Series data and documents — Manufacturer data (English)

High capacity pump models require three-phase, 60 Hz incoming power.

High capacity pump models are available as 208-230 VAC, 460 VAC or 575 VAC versions.

High capacity pump models are available in 3 hp and 5 hp versions.

STP-SCIII three-phase smart controllers and STP-CB3/5 three-phase control boxes are available for high capacity pump control.

50 Hz high capacity pump models require three-phase, 380-415 VAC incoming power.

50 Hz high capacity pump models are available in 3 hp and 5 hp versions.

STP-SCIIIC three-phase smart controllers and STPCBB3C and STP-CBB5C three-phase control boxes are available for high capacity pump control.

Fixed speed, 3450 rpm, multi-stage centrifugal type pump motor with built-in, automatic, thermal overload protection.

High capacity pump 60 Hz models are available as two-stage versions only.

Fixed speed, 2875 rpm, multi-stage centrifugal type pump motor with built-in, automatic, thermal overload protection.

Max. liquid viscosity: 70 SSU at 60 °F (15 °C).

Standard models are UL and cUL listed for fuel mixtures containing up to 10% ethanol and 20% MTBE, 20% ETBE or 17% TAME with gasoline.

STPAG models are compatible with fuel mixtures containing up to 85% ethanol and 20% MTBE, 20% ETBE or 17% TAME with gasoline.

HCP models can also be used with diesel fuels, fuel oils, kerosene, Avgas and jet fuels in a non-gelled pourable state.

All wetted elastomers are made of a high grade, fluorocarbon compound.

cULus listed.

Consult factory for applicable approvals.

Franklin Fueling Systems is an ISO 9001 Certified Manufacturer.

High Capacity Turbine Pumps - 60Hz

Model NumberDescription
401004901Submersible turbine pump 3 Hp 6", three-phase 208-230 VAC, 00" riser.
401005901Submersible turbine pump 5 Hp 6", three-phase 208-230 VAC, no riser.
401013901Submersible turbine pump 5 Hp 6", three-phase 575 VAC, no riser.

High Capacity Turbine Pumps - 50Hz

Model NumberDescription
401009901Submersible turbine pump 5 Hp 6", three-phase, 380-415 VAC, 50 Hz, no riser.
401008901Submersible turbine pump 3 Hp 6", three-phase, 380-415 VAC, 50 Hz, no riser.

6" STP Extractable

Model NumberDescription
HCPEXT-XXX6" fixed length extractable (XXX indicates Model Length, minimum 1524mm and amximum 5080mm)
Source page ↗ Franklin Electric Fueling Systems

About this product

Description