FE PETRO 1½ Hp — fixed-speed fuel pump – series illustration

Series illustration

FE PETRO 1½ Hp — fixed-speed fuel pump

The FE PETRO 1½ Hp fixed-speed pump serves fuel lines with relatively low throughput requirements. The range includes fixed and adjustable lengths and standard, AG and AP configurations. Read more →

Model code (SKU)PN-FF-STP150-VL1
Model
STP150-VL1
Factory order code
STP150-VL1
brands
FE PETRO / Franklin Electric
Configuration
Fixed speed
Power
1½ Hp
Length range
60" – 88"

Price

on request

Send an inquiry to receive prices and delivery terms within 1–2 days.

Send an inquiryContact us
  • Official dealer for 20+ brands
  • Delivery in Georgia
  • 20+ years of experience

Select a model by clicking its data in the table.

Compare models

ModelPowerLength range
1½ Hp60" – 88"
1½ Hp91" – 152"
1½ Hp123" – 214"
1½ Hp61" – 89"
1½ Hp92" – 152"
1½ Hp124" – 215"
1½ Hp60" – 88"
1½ Hp91" – 152"
1½ Hp123" – 214"
1½ Hp61" – 89"
1½ Hp92" – 152"
1½ Hp124" – 215"
1½ Hp60" – 88"
1½ Hp91" – 152"
1½ Hp123" – 214"
1½ Hp61" – 89"
1½ Hp92" – 152"
1½ Hp124" – 215"
Factory performance curve — 60 Hz
Factory performance curve — 60 Hz

This curve applies to the stated frequency and configuration. For 50 Hz use the corresponding document.

Construction, operation and model selection

Detailed description and use

System application and installation

Installed, grouped and component views

Two pumps on one tankA real factory photo shows two pumps in the tank service sump. Shared-line operation requires a suitable manifold and coordinated control.
Pump prepared for installationThe photo shows the full-length assembly, upper manifold and installation setting. Verify order code, length and compatibility on site.
Pump location and fuel path
MLD and coordinated multiple-pump control

Pump location and fuel path

The submerged PMA works inside the fuel tank; the upper manifold sits on the tank riser within the service sump. Its pressurized outlet feeds the dispensers, with a detector monitoring the delivery line. The electrical controller is separate, not submerged. A system photograph does not imply that all shown equipment is supplied in one kit.

Tank measurement and variable length

For variable-length STPs, measure from the tank bottom to the mounting-thread top. The manual’s example subtracts 6″ from 96″ to obtain 90″, allowing for bottom clearance and thread engagement. The telescopic section is then secured while keeping motor wires unstretched. This example does not replace measurements for the actual tank and ordered pump.

Why several pumps are manifolded

Manifolded pumps feed a shared delivery line. A correctly selected system can stage another pump as demand rises, distribute duty and provide service redundancy. Combined output depends on the individual pump curves, piping resistance and control mode; pump count alone does not determine the final flow.

MLD and coordinated multiple-pump control

TB013 requires only one lead pump during an MLD test. Two independently running detectors can yield an approximately 6 gph combined threshold instead of preserving the individual 3 gph protection. The document names suitable alternating/primary-secondary modes for STP-SCI/SCIII, MagVFC, SPGC-220 and TPGC-380. The drawing is not automatically applicable to other models.

Pressure and reverse flow in grouped systems

TB013 specifies suitable STD check valves with approximately 40 psi factory relief settings. Additional series check valves must not obstruct pressure relief. With pumps exceeding 40 psi connected across separate tanks, fuel may transfer into another tank; the document calls for additional overfill-control measures for that case.

Commissioning and servicing

Installation includes electrical isolation/lockout, grounding checks and fuel-compatible sealing. After connecting the hydraulics, commissioning removes air and checks pressure, leaks and the applicable protection functions. Replacement extractable parts must match their factory codes. The linked manual provides the complete procedure and configuration-specific electrical diagram.

Full installation manuals and drawings

Consult the specific model’s factory manual for the complete installation/service sequence, connections and safety requirements.

Factory video guides

Syphon jet cleaning and replacement

Syphon jet cleaning and replacement

Watch video ↗
4″ pump check-valve replacement

4″ pump check-valve replacement

Watch video ↗
Controller fault codes

Controller fault codes

Watch video ↗
Submersible fuel-pump installation

Submersible fuel-pump installation

Watch video ↗
PMA pump-motor assembly replacement

PMA pump-motor assembly replacement

Watch video ↗
Pump lead assembly replacement

Pump lead assembly replacement

Watch video ↗
Electrical yoke replacement

Electrical yoke replacement

Watch video ↗

1½ Hp fixed-speed fuel delivery

These 1½ Hp pumps serve pressurized fuel systems, with standard and high-pressure executions, lengths for different tank depths and fuel-compatible variants. Standard and high-pressure curves are assigned separately. Alcohol-compatible and Advanced Protection versions must be selected by their specific order codes.

Construction and tank fit

The assembly comprises the upper manifold, tank adapter, 4″ riser, column pipe, length coupler and lower PMA. The main outlet and leak-detector port are 2″ NPT; test and syphon ports are ¼″ NPT. Drawing dimensions A/B account for tank diameter, burial depth, adapters and bottom clearance.

Advanced Protection and MagShell options

Advanced Protection combines powder/E-coatings with stainless valves, hardware, riser/column pipes and PMA shells on applicable STPAG/IST executions, including demanding ULSD applications. MagShell for 2/4 Hp expands the flow area around the motor by 45%; this is an area increase, not a guaranteed 45% flow increase at every duty point.

Water and acid separation

The optional Corrosion Control Water Separator uses pump flow to create suction at the diesel tank bottom. Water/acid residue collects in a vessel while fuel returns to the tank. There is no replacement filter element; the source specifies service emptying two to three times yearly. An EVO console can manage cycles and level monitoring.

Air elimination, filtration and service

An active air eliminator and return path support fuel delivery. The IFS intake screen intercepts sediment and uses the small reverse flow on shutdown for cleaning. Electrical disconnects and pressure-relief elements support servicing. Confirm the presence of these features and accessories in the specific ordered configuration.

Control and leak monitoring

A variable-frequency controller adjusts speed to demand; fixed-speed Guardian protects the matching motor against load faults. EVO/TPI adds remote status, tank priorities and intake-restriction alerts. Mechanical and electronic line detectors provide separate leak monitoring. Select the controller, detector and enabled functions for the actual system.

Fuel blends and execution selection

Standard STP and Alcohol Grade STPAG/STPAP/IST/ISTAP have different blend approvals. The catalogue distinguishes E10/B5 standard equipment from applicable E85 and B20/B100 executions. It also lists 20% MTBE/ETBE or 17% TAME and fluorocarbon elastomers. Maximum viscosity is 70 SSU at 15°C. Confirm final compatibility against the exact order code.

Factory photos and details

Select an image to enlarge

Series overview
Series overview
Demand-based delivery
Advanced Protection and MagShell options
EVO/TPI remote-control capabilities
Series overview
Advanced Protection and MagShell options
Advanced Protection and MagShell options
Water and acid separation
Filtration and self-cleaning
Control and leak monitoring
Demand-based delivery
Fixed-speed pump control
Demand-based delivery
Demand-based delivery
Hydraulic system capability
Hydraulic hammer and energy use
EVO/TPI remote-control capabilities
Purpose and operation
Purpose and operation
Purpose and operation
Components and mounting dimensions
Factory performance diagram4 Inch Performance Chart -1.5 Hp Fixed Speed Pump Performance Chart
Factory performance diagram4 Inch Performance Chart -1.5 Hp High Pressure Fixed Speed Pump Performance Chart
Factory ordering and assembly diagram
STP mechanical and manifold parts
Two pumps on one tank
Pump prepared for installation
Pump location and fuel path
MLD and coordinated multiple-pump control

Descriptions include series-wide and optional features. Check the selected model’s table and documents for its actual configuration.

Original description and contents — STP150-VL1

Manufacturer data (English)

Standard 1½ Hp Fixed Speed Submersible Turbine Pumps

ModelSTP150-VL1
Description1½ Hp fixed speed
Model Length Range NumberVL1
Model Length Range*60" – 88"
Series data and documents — Manufacturer data (English)

1. Manhole

2. Leak Detector

3. Manifold

4. Containment Sump

5. 4" Riser

6. Tank Adapter

7. Tank Manway

8. Column Pipe

9. Variable Length Coupler

10. Pump Motor Assembly (PMA)

11. End bell

12. Line Test Port, ¼" NPT

13. Leak Detector Port, 2" NPT

14. Syphon Port, ¼" NPT

15. Tank Port, ¼" NPT

16. Riser Pipe, 4" NPT

17. Discharge Outlet, 2" NPT

Notes: 1. Effective tank diameter (ETD) = Inside tank diameter (to top of 4" bung), including tank manway and/or sump adapter.

2. Model length (A) = ETD plus riser length minus bottom clearance minus 1" thread engagement.

3. Riser length (B) = Bury depth (to top of tank) minus pump head clearance minus tank manway and/or minus sump adapter.

Biofuel Blend CompatibilityFE PETRO® pumps are UL listed with both UL79A (up to 85% Ethanol) and UL79B (up to 20% or 100% Biodiesel).

Variable LengthThe patented telescoping pump shaft lets installers adjust the length of the pump onsite for the perfect fit.

Advanced ProtectionStop corrosion in its tracks. Special powder-coated, e-coated, and stainless steel components defend your pump in the tank and in the sump from accelerated corrosion.

Turbine Pump InterfaceRemote enhanced pump monitoring and control including pump-in-water automation, clogged intake escalation, tank leveling, and tank priority.

Intake Filter ScreenAvoid system damage, pumping slowdowns, and reduce filter changes by keeping harmful tank debris, sediment, and corrosion from entering the pumping system with this factory-installed option.

Active Air EliminatorFE PETRO® STPs come standard with active air elimination, which eliminates air through the highest point in the pump head at all times when the pump is running, assuring air does not pass into discharge piping.

Safety and Ease of MaintenanceFE PETRO® STPs include a contractor electrical disconnect, which requires loosening only one bolt, allowing motor wiring to be disconnected without venting the dangerous tank vapors into the sump when servicing FE PETRO® submersible products.

Simple ServicingIf ever required, the pump can be easily removed from the tank by unthreading three bolts. There is no need to disconnect the syphon system or to remove the leak detector from the system to service the STP.

Manual Pressure ReliefAs a standard FE PETRO® feature, a vent screw is provided to bleed line pressure to zero when necessary. By turning this screw, product is diverted back to the tank, dropping line pressure to zero. This reduces fuel discharged into the sump manhole or dispenser pan during servicing, further protecting service technicians and the environment.

Outlast, Outperform with Franklin Electric InsideFE PETRO® STPs are powered by the legendary Franklin Electric motor and built for long term performance. Franklin Electric-powered submersible pumps provide maximum uptime and a proven track record in the fueling industry that spans more than four decades. They feature best-in-class flow rates and a long history of dependability.

Quality CertificationFranklin Fueling Systems is an ISO 9001 Certified Manufacturer.

1½ Hp fixed speed models are available in variable length and fixed length options.

Check valve: 2¾" diameter fluorocarbon seal constructed with cast aluminum body and steel backing washer.

Pressure relief valve: available in four pressure relief settings, integral to check valve. Standard model relieves at 40 psi and resets above 35 psi.

Syphon: venturi-type syphon primer supplied with every submersible. Syphon check valve and secondary syphon sold separately.

Air eliminator: every submersible includes a tank return path with one-way check valve to provide active air elimination.

Electrical disconnect: electrical yoke for positive contractor disconnect during service.

1½ Hp fixed speed, 3450 rpm, multi-stage centrifugal type pump motor with integral, automatic, thermal overload protection.

Standard pressure (150, two-stage) model, max. pressure = 32 psi.

High pressure (H150, three-stage) model, max.pressure = 45 psi.

1½ Hp fixed speed, 2875 rpm, multi-stage centrifugal type pump motor with integral, automatic, thermal overload protection.

Standard pressure (three-stage) model, max. pressure = 2.62 bar.

High pressure (four-stage) model, max. pressure = 3.31 bar.

1½ Hp fixed speed models require single-phase, 208-230 VAC, 60 Hz incoming power.

1½ Hp fixed speed models incorporate a starting and running capacitor, with internal bleed resistor, rated 370 Volt, 15 microfarad.

SPGC-220 single-phase Guardian Controllers and STP-CBS single-phase control boxes are available for 1½ Hppump control.

Max. motor draw: 11 Amps.

150B fixed speed models require single-phase, 200-250 VAC, 50 Hz incoming power. 150C fixed speed models require three-phase 380-415 VAV, 50 Hz incoming power.

150B fixed speed models incorporate a starting and running capacitor, with internal bleed resistor, rated 440 Volt, 15 microfarad.

SPGC single-phase Guardian™ Series Controllers and STP-CBBS single-phase control boxes are available for 150B pump control.

STP-SCIIC three phase controllers and STP-CBB3C three-phase magnetic starters are available for 150C control.

Max. motor draw: 150B 9 Amps, 150C 3 Amps.

Max. liquid viscosity: 70 SSU at 60 °F (15 °C).

Standard STP models are UL and cUL listed for fuel mixtures containing up to 10% ethanol with gasoline, and 20% MTBE, 20% ETBE or 17% TAME with gasoline.

STPAP/STPAG (AG compatible) models are UL listed for fuel mixtures containing diesel fuel with up to 20% Biodiesel, 100% Biodiesel, up to 85% ethanol with gasoline, and 20% MTBE, 20% ETBE or 17% TAMEwith gasoline.

1½ Hp fixed speed models can also be used with diesel fuels, fuel oils, kerosene, Avgas, and jet fuels in a non-gelled pourable state.

All wetted elastomers are made of a high grade, fluorocarbon compound.

STP Standard Submersible Turbine Pumps with Fixed or Variable Speed Pump Motor Assembly

UL79 for petroleum dispensing products intended for use with gasoline or gasoline/ethanol blends with nominal ethanol concentrations up to 10 percent (gasohol, E10), diesel fuel, diesel/biodiesel blends with nominal biodiesel concentrations up to 5 percent (B5), kerosene, or fuel oil.

20% MTBE, 20% ETBE or 17% TAME with gasoline.

STPAG, STPAP, IST, ISTAP Alcohol-Grade Compatible and Advanced Protection Fixed or Variable Speed Submersible Turbine Pumps

UL79A for gasoline and gasoline/ethanol blends with nominal ethanol concentrations up to 85 percent (E0 - E85) for products intended for use with gasoline or gasoline/ethanol blends with nominal ethanol concentrations up to 85 percent (E85).

20% MTBE, 20% ETBE or 17% TAME with gasoline.

UL79B for diesel fuel, biodiesel fuel, diesel/biodiesel blends with nominal biodiesel concentrations up to 20 percent (B20), kerosene, and fuel oil for products intended for use with diesel fuel, biodiesel fuel, diesel/biodiesel blends with nominal biodiesel concentrations up to 20 percent (B20), kerosene or fuel oil.

100% biodiesel.

cULus listed.

Consult factory for applicable approvals.

For 50 Hz performance charts, please see the 50Hz-Submersible Turbine Pumps-Datasheet in Downloads.

For 50 Hz performance charts, please see the 50Hz-Submersible Turbine Pumps-Datasheet in Downloads.

Standard 1½ Hp Fixed Speed Submersible Turbine Pumps

ModelDescriptionModel Length Range NumberModel Length Range*
STP150-VL11½ Hp fixed speedVL160" – 88"
STP150-VL21½ Hp fixed speedVL291" – 152"
STP150-VL31½ Hp fixed speedVL3123" – 214"
STPH150-VL11½ Hp high pressure fixed speedVL161" – 89"
STPH150-VL21½ Hp high pressure fixed speedVL292" – 152"
STPH150-VL31½ Hp high pressure fixed speedVL3124" – 215"

Alcohol-Gas (AG) 1½ Hp Fixed Speed Submersible Turbine Pumps

ModelDescriptionModel Length Range NumberModel Length Range*
STPAG150-VL11½ Hp AG fixed speedVL160" – 88"
STPAG150-VL21½ Hp AG fixed speedVL291" – 152"
STPAG150-VL31½ Hp AG fixed speedVL3123" – 214"
STPAGH150-VL11½ Hp AG high pressure fixed speedVL161" – 89"
STPAGH150-VL21½ Hp AG high pressure fixed speedVL292" – 152"
STPAGH150-VL31½ Hp AG high pressure fixed speedVL3124" – 215"
STPAP150-VL11½ Hp fixed speed with Advanced ProtectionVL160" – 88"
STPAP150-VL21½ Hp fixed speed with Advanced ProtectionVL291" – 152"
STPAP150-VL31½ Hp fixed speed with Advanced ProtectionVL3123" – 214"
STPAPH150-VL11½ Hp high pressure fixed speed with Advanced ProtectionVL161" – 89"
STPAPH150-VL21½ Hp high pressure fixed speed with Advanced ProtectionVL292" – 152"
STPAPH150-VL31½ Hp high pressure fixed speed with Advanced ProtectionVL3124" – 215"

Factory Installed Options

ModelDescription
FFloating suction adapter, 1½" NPT female, must be factory installed
KIFS (intake filter screen) factory assembled to pump motor assembly
RModel R check valve, factory installed, for Veeder-Root® PLLD Line Leak

1½ Hp fixed speed specific accessories - 60Hz

Model NumberDescription
400137908Syphon check valve, alcohol-gasoline compatible (when ordered with STP/IST)
400818921STP-CBS, single-phase control box, with switch and lockout, 120 Volt coil
402312931STP-DHI + SPGC-220 Guardian Series™ Single-Phase Controller bundle (220 Volt supply, 110 Volt hook)
402313921STP-DHI-CBS, combo DHI with factory-wired STP-CBS single-phase control box
402459931Model 65 psi check valve (for secondary manifolded STPs with Veeder-Root® PLLD), AG compatible
402507930Secondary syphon kit (when two syphon primes are required for one STP)
5800100220SPGC-220 Guardian Series™ Single-Phase Controller, 220 Volt
5800300100STP-DHI, dispenser hook isolation for 110 Volt dispenser handle switches, up to eight each

1½ Hp fixed speed specific accessories - 50Hz

Model NumberDescription
400137937Syphon check valve, alcohol-gasoline compatible
400818922STP-CBBS, single-phase control box, with switch and lockout, 240 Volt coil
401220965STP-CBB3C, three-phase 380-415 VAC magnetic starter
402312932STP-DHIB + SPGC-220 Guardian Series™ Single-Phase Controller bundle (220 Volt supply, 240 Volt hook)
402313922STP-DHIB-CBBS, combo DHI with factory-wired STP-CBBS single-phase control box
402459931Model 65 psi check valve (for secondary manifolded STPs with Veeder-Root® PLLD), AG compatible
402507930Secondary syphon kit (when two syphon primes are required for one STP)
5800100220SPGC-220 Guardian Series™ Single-Phase Controller, 220 Volt
5800300200STP-DHIB, dispenser hook isolation for 240 Volt dispenser handle switches, up to eight each
Source page ↗ Franklin Electric Fueling Systems

About this product

Description

The FE PETRO 1½ Hp fixed-speed pump serves fuel lines with relatively low throughput requirements. The range includes fixed and adjustable lengths and standard, AG and AP configurations. Check model length, voltage and fuel-blend compatibility against its ordering row and the appropriate 50 or 60 Hz document.