Series illustration
PENTAX DTR 400÷1000
Sewage drainage pumps. The grinder system allows the pumping of wastewater with suspended solids and prevents blockage of the pump. Read more →
Price
on request
Send an inquiry to receive prices and delivery terms within 1–2 days.
Send an inquiryContact us- Official dealer for 20+ brands
- Delivery in Georgia
- 20+ years of experience
Technical tables and curves
PENTAX · DTR-DTRT · 50 Hz
Select a model (7)
Select a model in the table to display its curve and data below.
| Model | Q range (m³/h) | H range (m) |
|---|---|---|
| 0–18 | 9.9–19.4 | |
| 0–18 | 13.4–22.1 | |
| 0–18 | 18.2–26.1 | |
| 0–18 | 21.6–33.5 | |
| 0–18 | 27.6–38.6 | |
| 0–18 | 36.1–47.8 | |
| 0–18 | 42.7–54.6 |
Technical sheet
Model DTR 150 / DTRT 150
Performance curve
The curve covers the range of the supplied table: 0-18 t/h. No data is provided outside this range.
- Table maximum head
- 19.4m
- Table maximum flow
- 18t/h
- Midpoint
- 14.2m
At zero flow
300 l/min· at 9.9 m
12 t/h ·
200 l/minat
Table values
| t/h | ||||||||
|---|---|---|---|---|---|---|---|---|
| l/min | ||||||||
| Head, m |
Select a number in the table to see the corresponding point.
Points come from the factory table; values between them use linear interpolation. PENTAX · 50 Hz · Source page 265 · 40 · 03/2026
About this product
Description
From the catalogue
Related products
Sewage pumps
PENTAX DTR 400÷1000

Description
PN.ge · PENTAX DTR 400÷1000
Technical tables and curves · DTR-DTRT · 50 Hz
Performance curve (Q–H)
Performance table
| Model | Q (t/h) | 0 | 3 | 6 | 9 | 12 | 13.2 | 15 | 18 |
|---|---|---|---|---|---|---|---|---|---|
| Q (l/min) | 0 | 50 | 100 | 150 | 200 | 220 | 250 | 300 | |
| DTR 150 / DTRT 150 | H (m) | 19.4 | 18.5 | 17.3 | 16 | 14.2 | 13.5 | 12.3 | 9.9 |
Q: flow; H: head at the corresponding flow.
Points come from the factory table; values between them use linear interpolation. PENTAX · Source page 265 · 40 · 03/2026