2HCP-160 – Centrifugal pump

2HCP-160 – Centrifugal pump

1.5 kW (2 HP) · Hmax 61 m · Qmax 6 t/h (100 l/min)

Nameplate data

Maximum flow8.7 t/h · 145 l/min
Maximum head52 m
Maximum suction lift9 m
Connection (inlet × outlet)1.25" × 1"
Power1.85 kW · 2.5 HP
MotorSingle-phase · 220 V · 50 Hz
Rotational speed2850 rpm
Rated current10.5 A
Maximum consumption2200 W
Capacitor40 µF · 450 V
Insulation classB
Protection classIP44
Operating dutyContinuous

Technical specifications

Select a value to find pumps with the same specification

Pump typeSurface – centrifugal
Maximum flow (Qmax)6 t/h · 100 l/min
Maximum head (Hmax)61 m
Power1.5 kW · 2 HP
SKU 2HCP-160

Price

on request

Send an inquiry to receive prices and delivery terms within 1–2 days.

Send an inquiryContact us
  • Official dealer for 20+ brands
  • Delivery in Georgia
  • 20+ years of experience

Series comparison

The entire series in one table

3 Model in one family, with head at each flow. The model you are viewing is highlighted in dark blue.

2HCP

This family
2HCP Family performance comparison
Modelt/h →l/min →Curve001.5253504.57561007.5125915010.51751220013.522515250
2HCP-1802.2 kW220 V6056.553484132.52210---
2HCP-160Current1.85 kW220 V615751.54537------
2HCP-2003 kW380 V6561.5595652474236292110
Table 1. 2HCP – columns show flow in t/h, with l/min below; cells show head in metres.

Source: manufacturer's technical sheet.Values are for reference. In a real system, pipe diameter, length and bends reduce the available head.

Technical sheet

Model 2HCP-160

Performance curve

A pump has a performance curve rather than a single flow and head. Qmax and Hmax are at opposite ends and never occur together: at maximum head, flow is zero; at maximum flow, head is zero. Actual operation lies between these extremes.

Hmax 61 mQmax6 t/h100 l/min02550t/h0123456l/min020406080100Head, mFlow
Maximum head
61m

At zero flow

Maximum flow
6t/h

100 l/min· at 37 m

Midpoint
51.5m

3 t/h
50 l/minat

Chart 1. Head (m) against flow (t/h, l/min), 2HCP-160. Blue points show the manufacturer's measured values. Move the pointer near the curve, or touch it on a phone, to read the head and flow at any point.

Measured values

Performance table
t/h
l/min
Head, m

Select a number in the table to see the corresponding point.

2HCP-160 – Centrifugal pump · PN.GE