2HCP-200 – Centrifugal pump

2HCP-200 – Centrifugal pump

3 kW (4 HP) · Hmax 65 m · Qmax 15 t/h (250 l/min)

Nameplate data

Maximum flow15 t/h · 250 l/min
Maximum head62 m
Maximum suction lift9 m
Connection (inlet × outlet)1.5" × 1.25"
Power3 kW · 4 HP
MotorThree-phase · 380 V · 50 Hz
Rotational speed2850 rpm
Rated current7.5 A
Insulation classB
Protection classIP44
Operating dutyContinuous

Technical specifications

Select a value to find pumps with the same specification

Pump typeSurface – centrifugal
Maximum flow (Qmax)15 t/h · 250 l/min
Maximum head (Hmax)65 m
Power3 kW · 4 HP
SKU 2HCP-200

Price

on request

Send an inquiry to receive prices and delivery terms within 1–2 days.

Send an inquiryContact us
  • Official dealer for 20+ brands
  • Delivery in Georgia
  • 20+ years of experience

Series comparison

The entire series in one table

3 Model in one family, with head at each flow. The model you are viewing is highlighted in dark blue.

2HCP

This family
2HCP Family performance comparison
Modelt/h →l/min →Curve001.5253504.57561007.5125915010.51751220013.522515250
2HCP-1802.2 kW220 V6056.553484132.52210---
2HCP-1601.85 kW220 V615751.54537------
2HCP-200Current3 kW380 V6561.5595652474236292110
Table 1. 2HCP – columns show flow in t/h, with l/min below; cells show head in metres.

Source: manufacturer's technical sheet.Values are for reference. In a real system, pipe diameter, length and bends reduce the available head.

Technical sheet

Model 2HCP-200

Performance curve

A pump has a performance curve rather than a single flow and head. Qmax and Hmax are at opposite ends and never occur together: at maximum head, flow is zero; at maximum flow, head is zero. Actual operation lies between these extremes.

Hmax 65 mQmax15 t/h250 l/min02550t/h02.557.51012.515l/min050100150200250Head, mFlow
Maximum head
65m

At zero flow

Maximum flow
15t/h

250 l/min· at 10 m

Midpoint
47m

7.5 t/h
125 l/minat

Chart 1. Head (m) against flow (t/h, l/min), 2HCP-200. Blue points show the manufacturer's measured values. Move the pointer near the curve, or touch it on a phone, to read the head and flow at any point.

Measured values

Performance table
t/h
l/min
Head, m

Select a number in the table to see the corresponding point.