FE PETRO DHI — dispenser hook isolation – series illustration

Series illustration

FE PETRO DHI — dispenser hook isolation

FE PETRO DHI optically isolates dispenser hook signals to prevent feedback between circuits. One device supports eight isolated inputs. Read more →

Model code (SKU)PN-FF-5800300100
Model
STP-DHI
Factory order code
5800300100
brands
FE PETRO / Franklin Electric
Dispenser hook signal
110 V
Isolated inputs
8

Price

on request

Send an inquiry to receive prices and delivery terms within 1–2 days.

Send an inquiryContact us
  • Official dealer for 20+ brands
  • Delivery in Georgia
  • 20+ years of experience

Select a model by clicking its data in the table.

Compare models

Model

Construction, operation and model selection

Detailed description and use

System application and installation

Installed, grouped and component views

Control lines from several dispensers

Control lines from several dispensers

Mount DHI on a wall or suitable base indoors in a non-hazardous area. It has its own supply, a hook output to the controller and up to eight isolated demand inputs. Servicing requires isolating every connected source; switching off one does not de-energize the other dispensers. Additional DHI units handle more than eight dispensers according to the relevant diagram.

Motor supply versus control signal

A starter or relay box has separate motor-power and dispenser-hook connections. Both voltages must match the specific wiring diagram. Its ON/OFF lockout switch does not replace full electrical isolation of the supply sources for servicing. The factory drawing represents its identified execution, not an interchangeable diagram for other ratings.

Checks before commissioning

First match motor and controller type, voltage, phases and frequency. Verify wiring, grounding and motor-lead insulation. Fixed-speed Guardian uses its calibration procedure; a variable-frequency model also requires frequency-limit and control-setting checks. Commissioning then tests dispenser demand, stopping and fault response.

Full installation manuals and drawings

Consult the specific model’s factory manual for the complete installation/service sequence, connections and safety requirements.

Optical isolation of dispenser signals

STP-DHI/STP-DHIB optically separates signals from up to eight dispensers. Isolation addresses relay-board damage from cross-phasing, feedback during servicing and false STP starts caused by leakage voltage from parallel dispensers. One unit is used per fuel grade for up to eight dispensers.

STP-DHI and STP-DHIB differences

STP-DHI uses 120 V / 30 VA supply and eight 120 V / 10 mA inputs; STP-DHIB uses 240 V / 30 VA and eight 240 V / 10 mA inputs. Output protection is a fast 250 V / 1 A fuse. Listed limits include 300 V surge protection, 120°F ambient and a 215 × 127 × 76 mm enclosure. LEDs show power and hook signals.

Separate unit or prewired combination

The unit works with submersible-pump controllers and can retrofit an existing site. Factory-prewired combinations pair it with SPGC-220 or a standard control box. Selection must match both the 110/120 V or 240 V hook signal and the contents of the particular bundle.

Factory photos and details

Select an image to enlarge

Control lines from several dispensers

Descriptions include series-wide and optional features. Check the selected model’s table and documents for its actual configuration.

Original description and contents — STP-DHI

Manufacturer data (English)

Intelligent submersible turbine pump specific accessories - 60Hz

Model Number5800300100
DescriptionSTP-DHI, dispenser hook isolation for 110 Volt dispenser handle switches, up to eight each

2 Hp fixed speed specific accessories - 60Hz

Model Number5800300100
DescriptionSTP-DHI, dispenser hook isolation for 110 Volt dispenser handle switches, up to eight each

Intelligent submersible turbine pump specific accessories - 60Hz

Model Number5800300100
DescriptionSTP-DHI, dispenser hook isolation for 110 Volt dispenser handle switches, up to eight each

1½ Hp fixed speed specific accessories - 60Hz

Model Number5800300100
DescriptionSTP-DHI, dispenser hook isolation for 110 Volt dispenser handle switches, up to eight each

¾ Hp fixed speed specific accessories - 60Hz

Model Number5800300100
DescriptionSTP-DHI, dispenser hook isolation for 110 Volt dispenser handle switches, up to eight each

STP-DHI

Model Number5800300100
DescriptionSTP-DHI, dispenser hook isolation for 110 Volt dispenser handle switches, up to eight each
Series data and documents — Manufacturer data (English)

Enclosure size: 8½" x 5" x 3" (215 mm x 127 mm x 76 mm).

Eight optically isolated inputs from dispenser.

One STP-DHI/STP-DHIB required per product grade for up to eight dispensers.

STP-DHI: 120 V 30 V A input from supply, eight 120 V 10mA inputs from dispensers.

STP-DHIB: 240 V 30 V A input from supply, eight 240 V 10mA inputs from dispensers.

Output fuse rating: 250 V 1A, fast-acting.

300 Volt surge protection.

Maximum ambient temperature rating: 120 °F.

LEDs indicate when source power is applied and dispenser hook signals are present.

Compatible with any submersible pump controller.

Consult factory for applicable approvals.

Franklin Fueling Systems is an ISO 9001 Certified Manufacturer.

STP-DHI

Model NumberDescription
402312931STP-DHI + SPGC-220 Guardian Series™ Single-Phase Controller bundle (220 Volt supply, 110 Volt hook)
5800300100STP-DHI, dispenser hook isolation for 110 Volt dispenser handle switches, up to eight each

STP-DHIB

Model NumberDescription
402312932STP-DHIB + SPGC-220 Guardian Series™ Single-Phase Controller bundle (220 Volt supply, 240 Volt hook)
5800300200STP-DHIB, dispenser hook isolation for 240 Volt dispenser handle switches, up to eight each

DHI Repair Parts and Accessories

Model NumberDescription
10000026753DHI fast-acting fuse, 250 VAC, 1 Amp
223885901DHI circuit board, 120 Volt dispenser hook signal

DHIB Repair Parts and Accessories

Model NumberDescription
10000026753DHI fast-acting fuse, 250 VAC, 1 Amp
223885931DHIB circuit board, 240 Volt dispenser hook signal
Source page ↗ Franklin Electric Fueling Systems

About this product

Description

FE PETRO DHI optically isolates dispenser hook signals to prevent feedback between circuits. One device supports eight isolated inputs. Choose DHI, DHIB or a bundle with SPGC-220; supply voltage and dispenser hook voltage are separate parameters.