MP 80 – Peripheral pump

MP 80 – Peripheral pump

Peripheral surface pump · 220V / 50Hz · 1" · 5 models

Nameplate data

Maximum flow3 t/h · 50 l/min
Maximum head65 m
Maximum suction lift8 m
Connection (inlet × outlet)1" × 1"
Power0.75 kW · 1 HP
MotorSingle-phase · 220 V · 50 Hz
Rotational speed2850 rpm
Rated current5.2 A
Maximum consumption1100 W
Capacitor20 µF · 450 V
Insulation classB
Protection classIP44
Operating dutyContinuous

Technical specifications

Select a value to find pumps with the same specification

Pump typeSurface – peripheral
Maximum flow (Qmax)3 t/h · 50 l/min
Maximum head (Hmax)65 m
Suction lift8 m
Power0.75 kW · 1 HP
Voltage / phase1 phase – 220V
Speed2850 rpm
Protection classIP44
Inlet (suction)1" (25 mm)
Outlet (discharge)1" (25 mm)
Insulation classB

Additional model data

Current5.2 A
Voltage220 V / 50 Hz
Connector1" × 1"
SKU MP-80

Price

on request

Send an inquiry to receive prices and delivery terms within 1–2 days.

Send an inquiryContact us
  • Official dealer for 20+ brands
  • Delivery in Georgia
  • 20+ years of experience

Series comparison

The entire series in one table

5 Model in one family, with head at each flow. The model you are viewing is highlighted in dark blue.

PM

This family
PM Family performance comparison
Modelt/h →l/min →Curve000.350.6100.9151.2201.5251.8302.1352.4402.745350
QB600.37 kW220 V353025201510.56.53---
QB700.75 kW230 V554943373023171285-
QB80Current0.75 kW220 V655952453831251914107
QB1000.75 kW220 V80-69-56-42-26--
QB1501.5 kW220 V90-80-64-48-30--
Table 1. PM – columns show flow in t/h, with l/min below; cells show head in metres.

Source: manufacturer's technical sheet.Values are for reference. In a real system, pipe diameter, length and bends reduce the available head.

Technical sheet

Model QB80

Performance curve

A pump has a performance curve rather than a single flow and head. Qmax and Hmax are at opposite ends and never occur together: at maximum head, flow is zero; at maximum flow, head is zero. Actual operation lies between these extremes.

Hmax 65 mQmax3 t/h50 l/min02550t/h00.511.522.53l/min01020304050Head, mFlow
Maximum head
65m

At zero flow

Maximum flow
3t/h

50 l/min· at 7 m

Midpoint
31m

1.5 t/h
25 l/minat

Chart 1. Head (m) against flow (t/h, l/min), QB80. Blue points show the manufacturer's measured values. Move the pointer near the curve, or touch it on a phone, to read the head and flow at any point.

Measured values

Performance table
t/h
l/min
Head, m

Select a number in the table to see the corresponding point.

MP 80 – Peripheral pump · PN.GE