HCm158 – Centrifugal pump

HCm158 – Centrifugal pump

0.75 kW (1 HP) · Hmax 32 m · Qmax 6.6 t/h (110 l/min)

Technical specifications

Select a value to find pumps with the same specification

Pump typeSurface – centrifugal
Maximum flow (Qmax)6.6 t/h · 110 l/min
Maximum head (Hmax)32 m
Power0.75 kW · 1 HP
SKU HCm158

Price

on request

Send an inquiry to receive prices and delivery terms within 1–2 days.

Send an inquiryContact us
  • Official dealer for 20+ brands
  • Delivery in Georgia
  • 20+ years of experience

Series comparison

The entire series in one table

2 Model in one family, with head at each flow. The model you are viewing is highlighted in dark blue.

HCm

This family
HCm Family performance comparison
Modelt/h →l/min →Curve000.6101.2201.8302.4403503.6604.2704.8805.49061006.61107.21207.8130
HCm158Current0.75 kWVoltage not confirmed3230.52927.525.82422.520.518.5161310--
HCm1901.5 kW220 V4140393836.53533.5323027.5252218.515
Table 1. HCm – columns show flow in t/h, with l/min below; cells show head in metres.

Source: manufacturer's technical sheet.Values are for reference. In a real system, pipe diameter, length and bends reduce the available head.

Technical sheet

Model HCm158

Performance curve

A pump has a performance curve rather than a single flow and head. Qmax and Hmax are at opposite ends and never occur together: at maximum head, flow is zero; at maximum flow, head is zero. Actual operation lies between these extremes.

Hmax 32 mQmax6.6 t/h110 l/min010203040t/h02468l/min050100Head, mFlow
Maximum head
32m

At zero flow

Maximum flow
6.6t/h

110 l/min· at 10 m

Midpoint
22.5m

3.6 t/h
60 l/minat

Chart 1. Head (m) against flow (t/h, l/min), HCm158. Blue points show the manufacturer's measured values. Move the pointer near the curve, or touch it on a phone, to read the head and flow at any point.

Measured values

Performance table
t/h
l/min
Head, m

Select a number in the table to see the corresponding point.

HCm158 – Centrifugal pump · PN.GE