HCm190 – Centrifugal pump

HCm190 – Centrifugal pump

1.5 kW (2 HP) · Hmax 41 m · Qmax 7.8 t/h (130 l/min)

Nameplate data

Maximum flow7.8 t/h · 130 l/min
Maximum head41 m
Maximum suction lift9 m
Connection (inlet × outlet)1" × 1"
Power1.5 kW · 2 HP
MotorSingle-phase · 220 V · 50 Hz
Rotational speed2850 rpm
Rated current8.6 A
Maximum consumption2200 W
Capacitor40 µF · 450 V
Insulation classB
Protection classIP44
Operating dutyContinuous

Technical specifications

Select a value to find pumps with the same specification

Pump typeSurface – centrifugal
Maximum flow (Qmax)7.8 t/h · 130 l/min
Maximum head (Hmax)41 m
Power1.5 kW · 2 HP
SKU HCm190

Price

on request

Send an inquiry to receive prices and delivery terms within 1–2 days.

Send an inquiryContact us
  • Official dealer for 20+ brands
  • Delivery in Georgia
  • 20+ years of experience

Series comparison

The entire series in one table

2 Model in one family, with head at each flow. The model you are viewing is highlighted in dark blue.

HCm

This family
HCm Family performance comparison
Modelt/h →l/min →Curve000.6101.2201.8302.4403503.6604.2704.8805.49061006.61107.21207.8130
HCm1580.75 kWVoltage not confirmed3230.52927.525.82422.520.518.5161310--
HCm190Current1.5 kW220 V4140393836.53533.5323027.5252218.515
Table 1. HCm – columns show flow in t/h, with l/min below; cells show head in metres.

Source: manufacturer's technical sheet.Values are for reference. In a real system, pipe diameter, length and bends reduce the available head.

Technical sheet

Model HCm190

Performance curve

A pump has a performance curve rather than a single flow and head. Qmax and Hmax are at opposite ends and never occur together: at maximum head, flow is zero; at maximum flow, head is zero. Actual operation lies between these extremes.

Hmax 41 mQmax7.8 t/h130 l/min01020304050t/h02468l/min050100Head, mFlow
Maximum head
41m

At zero flow

Maximum flow
7.8t/h

130 l/min· at 15 m

Midpoint
32m

4.2 t/h
70 l/minat

Chart 1. Head (m) against flow (t/h, l/min), HCm190. Blue points show the manufacturer's measured values. Move the pointer near the curve, or touch it on a phone, to read the head and flow at any point.

Measured values

Performance table
t/h
l/min
Head, m

Select a number in the table to see the corresponding point.

HCm190 – Centrifugal pump · PN.GE