FE PETRO MagVFC — 220 V variable frequency controller

Series illustration

FE PETRO MagVFC — 220 V variable frequency controller

MagVFC controls a compatible FE PETRO 2 Hp or 4 Hp variable-speed pump. The manufacturer lists it as a distinct 220 V controller. Read more →

Technical specifications

Model code (SKU)PN-FF-5874202800
Model
MagVFC
Factory order code
5874202800
brands
FE PETRO / Franklin Electric
Frequency
60 Hz
Nominal supply
220 V
Power
2 / 4 Hp

Price

on request

Send an inquiry to receive prices and delivery terms within 1–2 days.

Send an inquiryContact us
  • Official dealer for 20+ brands
  • Delivery in Georgia
  • 20+ years of experience

Construction, operation and model selection

Detailed description and use

System application and installation

Installed, grouped and component views

Pump prepared for installationThe photo shows the full-length assembly, upper manifold and installation setting. Verify order code, length and compatibility on site.
Two pumps on one tankA real factory photo shows two pumps in the tank service sump. Shared-line operation requires a suitable manifold and coordinated control.
MLD and coordinated multiple-pump control

Where the controller is mounted

Choose mounting location and cabling from the specific controller manual. Guardian guides specify indoor, non-hazardous locations, not a sump containing fuel vapours. Provide grounding, secure enclosure mounting and cooling clearance. Motor, incoming supply, dispenser-hook and RS485 connections serve different functions.

Checks before commissioning

First match motor and controller type, voltage, phases and frequency. Verify wiring, grounding and motor-lead insulation. Fixed-speed Guardian uses its calibration procedure; a variable-frequency model also requires frequency-limit and control-setting checks. Commissioning then tests dispenser demand, stopping and fault response.

Why several pumps are manifolded

Manifolded pumps feed a shared delivery line. A correctly selected system can stage another pump as demand rises, distribute duty and provide service redundancy. Combined output depends on the individual pump curves, piping resistance and control mode; pump count alone does not determine the final flow.

MLD and coordinated multiple-pump control

TB013 requires only one lead pump during an MLD test. Two independently running detectors can yield an approximately 6 gph combined threshold instead of preserving the individual 3 gph protection. The document names suitable alternating/primary-secondary modes for STP-SCI/SCIII, MagVFC, SPGC-220 and TPGC-380. The drawing is not automatically applicable to other models.

Pressure and reverse flow in grouped systems

TB013 specifies suitable STD check valves with approximately 40 psi factory relief settings. Additional series check valves must not obstruct pressure relief. With pumps exceeding 40 psi connected across separate tanks, fuel may transfer into another tank; the document calls for additional overfill-control measures for that case.

Controllers, EVO and communication

In a networked installation, RS485 coordinates compatible pumps and EVO/TPI monitoring; it does not replace motor power wiring. The manual defines addressing, operating mode and supported devices. Commissioning checks communication indication and received statuses. Network features are not automatically available on every standalone control box.

Full installation manuals and drawings

Consult the specific model’s factory manual for the complete installation/service sequence, connections and safety requirements.

Factory video guides

TPI interface wiring installation

TPI interface wiring installation

Watch video ↗

MagVFC power and compatibility

MagVFC is a 220 V-class controller for compatible FE PETRO variable-speed pumps only. The source gives 200–250 VAC, 50/60 Hz input. A 2 Hp execution may use single-phase input; VS4/4 Hp requires three-phase input. Output to the motor is three-phase variable frequency; maximum line draw is listed as 20 A.

Demand-based delivery

Frequency control changes pump speed with the number of active dispensers. It reduces motor power at low demand and raises speed during peaks, helping maintain steadier delivery. Actual performance depends on the pump, piping and selected operating pressure.

Hydraulic hammer and energy use

Abrupt flow interruption can cause a pressure surge. Speed regulation limits excess pressure and reduces stress on valves, detectors and dispenser components. Matching power to demand can lower energy use at partial load; no fixed saving percentage is specified.

Hydraulic system capability

The source’s sizing example gives 10 gpm (about 38 L/min) per nozzle for up to eight simultaneous positions at 2 Hp or twelve at 4 Hp. Maximum pump flows are 110 and 140 gpm. These are pump/controller system figures requiring suitable piping and dispensers, not controller-only ratings.

Factory photos and details

Select an image to enlarge

EcoVFC 380 V-class system
Hydraulic system capability
Hydraulic hammer and energy use
MagVFC power and compatibility
Pump prepared for installation
Two pumps on one tank
MLD and coordinated multiple-pump control

Descriptions include series-wide and optional features. Check the selected model’s table and documents for its actual configuration.

Original description and contents — MagVFC

Manufacturer data (English)

Intelligent submersible turbine pump specific accessories - 60Hz

Model Number5874202800
DescriptionMagVFC™, 2 Hp or 4 Hp Variable Frequency Controller, 220 V, one required per STP

2 Hp fixed speed specific accessories - 60Hz

Model Number5874202800
DescriptionMagVFC™, 2 Hp or 4 Hp Variable Frequency Controller, 220 V, one required per STP

Intelligent submersible turbine pump specific accessories - 60Hz

Model Number5874202800
DescriptionMagVFC™, 2 Hp or 4 Hp Variable Frequency Controller, 220 V, one required per STP
Series data and documents — Manufacturer data (English)

Variable speed models are available in variable lengths only.

Check valve: 2¾" diameter fluorocarbon seal constructed with cast aluminum body and steel backing washer.

Pressure relief valve: available in four pressure relief settings, integral to check valve. Standard model relieves at 40 psi and resets above 35 psi.

Syphon: venturi-type syphon primer supplied with every submersible. Syphon check valve and secondary syphon sold separately.

Air eliminator: every submersible includes a tank return path with one-way check valve to provide active air elimination.

Electrical disconnect: electrical yoke for positive contractor disconnect during service.

2 hp or 4 hp, variable speed, two-stage centrifugal type pump motor with integral, automatic, thermal overload protection.

Max. flow: 2 hp = 110 gpm, 4 hp = 140 gpm.

Max. pressure: selectable operating pressure on MagVFC™ between 24 psi and 42 psi deadhead.

Available with MagShell™, which results in 45% increased flow area around motor.

IST models can only be powered by a MagVFC™ or EcoVFC™ controller:

2 hp models can operate with single phase incoming power supply to the MagVFC™.

2 hp and 4 hp models operate with three-phase incoming power supply to the EcoVFC™.

Incoming power supply to the MagVFC™ can be 200-250 VAC, 50 Hz and 360-440 VAC, 50 Hz for the EcoVFC™.

MagVFC™ outputs a three-phase, variable frequency signal, valid for FE Petro variable speed pumps only.

2 hp max. motor draw: 9 Amps.

4 hp max. motor draw: 15 Amps.

MagVFC™ max. line draw: 20 Amps.

Max. liquid viscosity: 70 SSU at 60 °F (15 °C).

IST models imply alcohol-gasoline compatibility for fuel mixtures containing up to 85% ethanol, and 20% MTBE, 20% ETBE or 17% TAME with gasoline.

IST models can also be used with diesel fuels, fuel oils, kerosene, Avgas and jet fuels in a non-gelled pourable state.

All wetted elastomers are made of a high grade, fluorocarbon compound.

Consult factory for applicable approvals.

Franklin Fueling Systems is an ISO 9001 Certified Manufacturer.

Variable Frequency Controllers

Model NumberDescription
5874202900EcoVFC™, 2 Hp or 4 Hp Variable Frequency Controller, 380 V, one required per STP
Source page ↗ Franklin Electric Fueling Systems

About this product

Description

MagVFC controls a compatible FE PETRO 2 Hp or 4 Hp variable-speed pump. The manufacturer lists it as a distinct 220 V controller. Use the matching MagVFC supply, installation and pump compatibility documents; the EcoVFC 380 V is a separate configuration.